Wiring Diagram

Turn on the Electric:

Once the electrical is “live”, you need to program and test the phone. Reconnect the Wago connectors that 

attach the front plate to the NEMA box. If the phone will be programmed remotely, secure the front assem-

bly to the back panel, install the top cap, and reinstall the 12 screws to the sides of the unit. Otherwise, 

proceed to the directions for Programming the Phone On-Site.

Wago

Transformer

Ground

10 conductor cable to front plate

Battery

Wago Connector 10 contact

Water proof wire nuts for

Hot, Neutral, and Ground

Phone line

connect with 

Water proof connections

Pair of wires 

for Camera

Pair of wires 

for Strobe

1

4

5

7

8

0

9

6

3

2

Enter

Record

Play / Pause

Stop

*

#

Annunciator Audio

Connector

Hot

Neutral

To Constant Strobe

Summary of Contents for 2100-CPV

Page 1: ...Operations Manual C O M M U N I C A T I O N S E M E R G E N C Y N56 W24720 N Corporate Circle Sussex WI 53089 866 850 8854 262 246 4828 fax www rathsecurity com Made in the USA 2 Year Warranty 2100 C...

Page 2: ...ervice and support Our 1 mission is customer satisfaction When evaluating emergency communication systems you can rely on Rath to continually provide Innovative Thinking Design and Value Thank you for...

Page 3: ...ttach unit to pole using a secure mounting fastener 7 Connect the electrical conduit of the 110ac volt supply to the call station and run necessary wires 8 Connect the 110ac wiring to the call station...

Page 4: ...assem bly to the back panel install the top cap and reinstall the 12 screws to the sides of the unit Otherwise proceed to the directions for Programming the Phone On Site Wago Transformer Ground 10 c...

Page 5: ...ion message A To turn on message Press 1 3 Enter 2 B Press 6 Record speak message Stop to replay message Press 6 Play C For no message Press 1 3 Enter 0 Step 4 To exit program mode A Press Stop for 3...

Page 6: ...ted Ongoing Testing of the Phone Rath recommends that the Emergency call stations be tested and maintained on a monthly basis to ensure proper operation For testing follow the procedure outlined in Te...

Page 7: ...called party hangs up strobe continues to flash for 1 minute Slow disconnecting signal from the phone company This is considered normal operation When called party hangs up strobe continues to flash P...

Page 8: ...Tower Dimensional Specifications pg 7 C O M M U N I C A T I O N S E M E R G E N C Y 866 850 8854 www rathsecurity com Body of Tower Height 36 in Width 10 in Depth 8 in Thickness of Steel 18 gauge Wei...

Page 9: ...vered under this warranty Rath s liability under this warranty shall be solely limited to the repair or replacement of the defective parts within the warranty period and will not be liable under any c...

Reviews: