pg. 6
Testing of the Phone:
Push the silver emergency button on front of the Call Station:
Adjusting the Volume:
If the volume is too low or high, adjust it by referring to the diagram and instructions below.
*Note - Refer to the instructions under “Programming the Phone” to access the circuit board.
Adjusting the Microphone:
If the person you are calling reports your voice is not loud enough, increase the Microphone Sensitivity by
adjusting VR2 ¼ turn clockwise (requires a small Phillips screwdriver).
Adjusting the Speaker:
If the voice of the person you call is not loud enough in the emergency phone speaker, increase the
volume, by adjusting VR1 ¼ turn clockwise.
Reinstall the cover on the NEMA enclosure and secure the rear access panel.
Suggested Ongoing Testing of the Phone:
Rath recommends that the Emergency Call Station be tested and maintained on a monthly basis to ensure
proper operation. For testing, follow the procedure outlined in “Testing of the Phone”.
Do you hear a dial tone?
Does the Strobe start flashing immediately when button was pushed?
Does red LED become a solid light when you pushed the button?
Does the red LED flash and a short time after (15-20 seconds) the called party started talking
to you? (Delay is due to phone telling other party your location via the “Location Message”)
Can you hear the other party clearly? (if no, see “Adjust Speaker” on the next page)
Can the other party hear you clearly? (If no, see “Adjust Microphone” on the next page)
When the party you called hangs up, does the strobe stop?
Yes
No
If you have answered YES to all questions, you have successfully installed and tested your new
emergency phone. If you answer no to any question, proceed to the Troubleshooting section.
www.rathsecurity.com