background image

Ratek OM8 Orbital Shaker – User Manual 

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

Page 9 of 15

 

 
The mains power supply must be rated to match the power requirement as identified on the product identification label on the 
bottom left corner of the rear panel. This is normally expressed in the format of Voltage Range and Frequency. 
 

A surge protected power outlet is strongly recommended as it provides some protection for the equipment in areas of 
poor electrical quality as well as providing some protection against lightning strikes. The equipment should be 
operated on a good, reliable supply of power at all times. 
 

Note: The Orbital Shaker should not be operated on the same electrical circuit as other high voltage household appliances such 
as fridges, clothes dryers, washing machines or other continuous operation high voltage devices. These types of devices can 
create power fluctuations that are undesirable for electrically sensitive equipment. Consult your workplace administrator or 
electrical maintenance staff if you are unsure. 

 
IMPORTANT: Use of an incorrect power supply will void the product warranty and waive all manufacturer liability for 
any and all damage caused by such use. If you are unsure about the rating of your power supply, consult your 
workplace administrator or electrical maintenance staff to determine if your power supply is suitable for use with this 
product before connecting the power lead. 

 

 

 

CAUTION 

Regularly check the mains power lead condition over the life of the product, and do not operate the equipment if you suspect 
there is damage to any part of the equipment or the mains power lead.

 

 

-

 

Insert the plug end of the mains power supply lead firmly into a properly rated, protective earthed wall mounted power 
supply outlet. 

 
If there are double-adapters or oversized DC power packs causing obstruction of the mains power lead plug, these should first 
be removed. 

 

-

 

Ensuring your hands are dry, switch on the power on the mains power supply outlet. 

 

 

 

Operating the Orbital Shaker

 

 

 

 

CAUTION 

When working with glass tubes, flasks, bottles, breakable or other brittle or fragile articles it is important to wear appropriate 
safety eyewear and protective gloves to ensure operator safety. In addition, the Orbital Shaker should be used in accordance 
with your operational health and safety policies. 

 

 

 

-

 

Load your items evenly around the platform to present a balanced load to the mixer 

-

 

Ensure that there are no obstructions which would prevent proper rotation of the platform. 

-

 

Switch on the power. 

-

 

Select the desired agitation speed. Refer to the section in this User Manual titled “Adjusting The Mixing Control” for 
instructions. 

-

 

The speed may be adjusted as desired. 

-

 

Remove the items once mixing is complete. 

-

 

If the mixer is no longer being used, switch the power to Off (element 1 in Figure 1) 

 

 

 

Adjusting The Mixing Control

 

 

 

 

The Orbital Shaker features adjustable mixing speed control to deliver gentle agitation through to vigorous mixing.  
 

For Manual Operation 

-

 

Press the power switch to on

 

-

 

Press Select/Reset to cancel the timer

 

-

 

Set the desired speed by pushing the up/down arrows (Single push for single digit adjustments, or hold down for fast 
scrolling)

 

-

 

Push the Start/Stop button to begin.  (After 3-4 seconds the mixer will start and will slowly increase to set speed.)

 

-

 

Speed can be altered up or down while in use, if required.

 

 

 

For Timed Operation 

-

 

Press Select/Reset to select hours or minutes, then set to the required time

 

-

 

Set the desired speed by pushing the up/down arrows (Single push for single digit adjustments, or hold down for fast 

Summary of Contents for OM8

Page 1: ...015 English www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made in Australia User Manual printed in Australia...

Page 2: ...the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the product into the supplied...

Page 3: ...TY CONSIDERATIONS 5 5 5 5 Conditions of Operation 5 Safety Labels And Markings 6 OPERATING PROCEDURES 6 6 6 6 Identification of Controls Functions 6 Safety Warnings 7 Safety Recommendations 7 Preparat...

Page 4: ...r the Operator Any item that is not suitably secured to the mixing platform Suitable Environments For The Orbital Shaker The Orbital Shaker is intended for use in a clean laboratory environment only w...

Page 5: ...ng in how to perform their work safely in accordance with any local operational health and safety regulations The operator and all users should be well versed in local emergency procedures as per the...

Page 6: ...as a rotating platform which should not be touched whilst it is moving Keep all body parts away from the moving platform whilst in operation Always stop the platform using the front panel speed contro...

Page 7: ...kplace administrator or electrical maintenance staff to determine if a protective earth power socket is available A surge protected power outlet is strongly recommended as it provides some protection...

Page 8: ...inimum unobstructed distance of 500 millimetres in front of the Orbital Shaker to allow adequate room for the user to maintain a safe operating distance of 300 millimetres CAUTION The Orbital Shaker i...

Page 9: ...erly rated protective earthed wall mounted power supply outlet If there are double adapters or oversized DC power packs causing obstruction of the mains power lead plug these should first be removed E...

Page 10: ...weight The counterweight is located beneath the platform carrier It is adjustable and has 4 positions The counterweight should be set for the expected load to enable the shaker to operate smoothly wit...

Page 11: ...overed bars The bars can be moved horizontally enabling flasks test tube racks and most other types of containers to be secured to the platform TCT25 Tulip Clip Tray This tray is suitable for holding...

Page 12: ...d receptacles are completely dry before restoring electrical power Unplug the equipment from the mains power supply outlet Allow the Orbital Shaker to air dry or use a dry cloth to remove water from a...

Page 13: ...etres Temperature 0 Celsius to 45 Celsius Maximum relative humidity 80 for temperatures up to 31 Celsius decreasing linearly to 50 relative humidity at 40 Celsius MAINS supply voltage fluctuations up...

Page 14: ...a 3 year parts and 12 months labour return to base warranty effective from the date of purchase The product is manufactured in Melbourne Australia The warranty is offered by Ratek Instruments Pty Ltd...

Page 15: ...refund Ratek Instruments will pay your reasonable direct expenses of claiming under this Warranty You may submit details and proof of your expense claim to Ratek Instruments for consideration This Wa...