28
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
Step three: open piping hole
2. Open a piping hole with the diameter o
f Φ55
or Φ70
on the selected outlet pipe
position.In order to drain smoothly , slant the piping hole on the wall slightly
downward to the outdoor side with the
gradient of 5-10°.
Left
Wall
Φ70mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ70mm
Rear piping hole
RS-V12KE:
RS-V18KE&RS-V24KE:
RS-V9KE:
Left
Wall
Φ55
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55
Rear piping hole
Left
Wall
Φ55
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55
Rear piping hole
3. Fix the wall-mounting frame on the wall with tapping screws
(
ST4.2x25TA
)
and
then check if the frame is firmly installed by pulling the frame. If the plastic
expansion particle is loose, please drill another fixing hole nearby.