7. Energy-

Saving Mode (Default is “OFF”)

 

7.1 After the filter life setting is completed, press      to enter energy-saving 

setting status. Press      

to “ON” and      to “OFF” energy

-saving mode. 

7.2 If the energy-saving sensor detects less than 0.5Lux for more than 3 

minutes (Dark environment), machine will enter energy-saving mode. 

Description of Energy-saving mode: 

1. Under energy-saving mode, all lights except      will turn off. Heating 

and cooling functions will cease working. 

2. If any button is touched, machine will exit energy-saving mode 

immediately and resume all functions. Machine will also exit energy-

saving mode if energy-saving sensor detects light intensity of above 

0.5Lux for more than 30s. 

8. End setting 

8.1 When energy-saving mode is completed, press      to exit setting mode. 

Display window will go back to display the time. Pressing      will 

immediately exit the setting mode. 

 
Standby Status: 

When the machine is not operated for more than 10 minutes, it will enter 

standby status, where all lights except the clock and dispenser button will 
turn off. Heating and cooling systems will continue to operate normally. 

Press any button to exit standby status. 

 

 

Summary of Contents for HCM-T1

Page 1: ...rights reserved RASLOK is a trademark of RASLOK Pte Ltd Singapore Website www raslok com Email sales raslok com Design and color may differ from the picture Unit appearance specification etc are subje...

Page 2: ...3 NOTICE 4 Product Description General Overview 5 Touch Panel Operation User Interface 6 Description of Button Operation 8 System Settings 9 Diagrams of Machine s internal workings 13 Troubleshooting...

Page 3: ...damage NOTICE Indicates a situation which if not avoided could result in property damage WARNINGS About the Power Supply To reduce the risks associated with hazardous voltage and fire Do not plug inm...

Page 4: ...in direct sunlight or outdoors exposed to rain snow The equipment is designed for indoor use only Large amount of moisture or dust in the equipment surroundings may damage the equipment Do not tilt t...

Page 5: ...Interface UI 2 Decorative plate 3 Waterspout 4 Front Panel 5 Top Cover 6 Drip Collector 7 Control Panel 8 Side Panel 9 Black Panel 10 Power Cord 11 Water Inlet 12 Heating System Switch 13 1st Filter...

Page 6: ...hen the machine is heating and turn back white when heating is finished light will remain red during dispensing of hot water Press any Button to stop dispensing 2 Clock Timer White light used to displ...

Page 7: ...red after being pressed until extra hot heating is completed 7 Water Dispensing Mixed Water Setting Confirm Button Red White lights Press button after pressing or to dispense cold or hot water respec...

Page 8: ...turn back white Press any button during dispensing to stop immediately Note 1 Pressing Button before or after button will allow you to select the predetermined volume 2 Button will turn blue when the...

Page 9: ...aying the set hot water temperature Press to increase and to decrease Hot water temp range is 40 94 C 3 Extra hot water temperature Default is 95 C 3 1 After the hot water temperature setting is compl...

Page 10: ...er product batches and or versions 6 Filter Lifespan Setting 6 1 After the UVC LED Sterilizer setting is completed press to enter Filter lifespan setting mode status will start flashing to show the fi...

Page 11: ...Tray Item No Description Function Lifespan HCMT1 F1 Sediment Carbon Composite Sediment removes sand dust impurities rust and other substances Carbon removes odors colors residual chlorine and organic...

Page 12: ...y button is touched machine will exit energy saving mode immediately and resume all functions Machine will also exit energy saving mode if energy saving sensor detects light intensity of above 0 5Lux...

Page 13: ...Page 13 of 18 Diagrams of Machine s internal workings Circuit Diagram WATERWAY...

Page 14: ...t the end about 30mm of the tubing to make sure there are no nicks scratches or rough spots Cut the tubing again if needed Connect tubes 1 Push tubing through collet until it engages the O ring Contin...

Page 15: ...locking of air inlet and outlet 5 Drip tray must be properly placed within the counter Do not suspend it mid air or it may fall off 6 Take out the blue securement clip at the rear of the product s bas...

Page 16: ...e machine on a steady and solid surface Machine fails to run Insufficient power supply Switch on power supply E1 00 Cold water NTC error Contact the local service agency for support Heating and coolin...

Page 17: ...put Hot water Temp range Extra Heating Temp range 5L H 40 94 C set point 5 C 85 96 C set point 5 C 4 1st Sediment Activated carbon block composite 2nd UF Membrane ACF composite 1st Lifespan 2100L 550G...

Page 18: ...and use instructions This warranty gives you specific legal rights in Singapore and you may have other rights which may vary from country to country Limitation of Liability RASLOK Pte Ltd will not be...

Reviews: