background image

Rasha Professional A/S 1800 Rustin Ave., Riverside CA, 92507 

951-654-3585

rashaprofessional.com 

|

|

 [email protected]

5

Safety Notes 

Read all the following Safety Notes before working with this product. These 

notes include important information about the installation, usage, and 

maintenance of this product. This product contains no user-serviceable 

parts. Any reference to servicing in this User Manual will only apply to 

properly trained Rasha certified technicians. Do not open the housing or 

attempt any repairs. All applicable local codes and regulations apply to 

proper installation of this product. 

Personal 

Safety 

Avoid direct eye exposure to the light source while the product is on. Always 

disconnect this product from its power source before servicing. Always 

connect  this  product  to  a  grounded  circuit  to  avoid  the  risk  of  electrocution.                                                                                                       

Do not touch this product’s housing during operation because it may be 

very hot. 

Rigging 

This  product  is  for  indoor  use  only! To  prevent  risk  of  fire  or  shock,  do 

not expose this product to rain or moisture. (IP20) CAUTION: When 

transferring product from extreme temperature environments, (e.g. Cold 

truck to warm humid ballroom) condensation may form on the internal 

electronics of the product. To avoid causing a failure, allow product 

to fully acclimate to the surrounding environment before connecting it 

to power. Mount this product in a location with adequate ventilation, 

at least 20 in (50 cm) from adjacent surfaces. Make sure there are 

no  flammable  materials  close  to  this  product  while  it  is  operating.  

                                                                                                     Always carry 

this product by the handles. Do not carry from the head. When hanging this 

product, always secure to a fastening device using a safety cable.

Power And 

Wiring

Always make sure you are connecting this product to the proper voltage 

in accordance with the specifications in this manual or on the product’s 

specification label. Never connect this product to a dimmer pack or rheostat. 

Never disconnect this product by pulling or tugging on the power cable.  

Operation 

Do not operate this product if you see damage to the housing, lenses, 

or cables. Have the damaged parts replaced by an authorized 

technician at once. To eliminate unnecessary wear and improve 

its lifespan, during periods of non-use completely disconnect the 

product from power via breaker or by unplugging it. Do not cover the 

ventilation slots when operating to avoid internal overheating. Do not 

aim this product toward the Sun. The lenses could concentrate the 

solar energy and cause internal overheating. The maximum ambient 

temperature is 113 °F (45 °C). Do not operate this product at a 

 

higher temperature. In case of a serious operating problem, stop using this 

product immediately!

The term “DMX” used throughout this manual refers to the  DMX512 digital data 

transmission protocol

Summary of Contents for K2

Page 1: ...RASHA PROFESSIONAL A S Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 rashaprofessional com info rashaprofessional com 1 QUICK USER MANUAL K2...

Page 2: ...rks and resources Copyright 2015 RASHA All rights reserved Electronically published by Rasha in the United States of America Manual Use Rasha authorizes its customers to download and print this manual...

Page 3: ...s 5 Personal Safety 5 Mounting And Rigging 5 Power And Wiring 5 Operation 5 2 Introduction 6 Description 6 Features 6 Overview 6 Dimensions 7 3 Setup 8 Power Supply 7 AC Plug 8 Fuse Replacement 8 Powe...

Page 4: ...er immediately may Void your claim In addition keep the box and contents for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a c...

Page 5: ...the surrounding environment before connecting it to power Mount this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Make sure there are no flammable mater...

Page 6: ...h and parallel beam luminaire for small to big event production venues arenas TV studio Fitted with 19 LED emitters K2 delivers luminous flow of over 10000 lumen over powering conventional luminaire K...

Page 7: ...Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 rashaprofessional com info rashaprofessional com 7 DIMENSIONS...

Page 8: ...utrik powerCON A connector on one end and an Edison plug on the other end U S Market If the power input cord that came with your product has no plug or if you need to change the Edison plug use the ta...

Page 9: ...affect the product If hanging this product make sure that the mounting location can support the product s weight See the Technical Specifications for the weight bearing requirements of this product Wh...

Page 10: ...Show 3 Selects and sets Preset light show mode 3 Fixture must be master Show 4 Selects and sets Preset light show mode 4 Fixture must be master Slave Mode Slave 1 Selects and save fixture on Slave Mo...

Page 11: ...and sets Dimmer frequency to 2400K 4000K Selects and sets Dimmer frequency to 4000K 6000K Selects and sets Dimmer frequency to 6000K Fan Speed Auto Selects and sets auto fan speed Slow Selects and set...

Page 12: ...5 pin XLR cable to link the unit and the DMX controller DMX512 link use 3 5 pin XLR cable to link the next unit and output DMX signal PowerCon connection from main power supply 3 Button 7 Mains OUT Po...

Page 13: ...ut Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209 Al...

Page 14: ...ed full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down Green 0 Blue full White 0 247 Blue Red 0 Green 0 Blue full White...

Page 15: ...ckout Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209...

Page 16: ...ue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down...

Page 17: ...ving Blackout Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan Tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL...

Page 18: ...l Blue 0 White 0 135 Yellow Red full Green full Blue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta R...

Page 19: ...Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan Tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209 All Reset 210 255 NULL 7CH Zoom 000 255 8CH Zoom Fine 000 255 9CH Shut...

Page 20: ...Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down Green 0 Blue full Wh...

Page 21: ...180 189 Zoom Reset 190 199 NULL 200 209 All Reset 210 255 NULL 7CH Red1 000 255 8CH Red Fine 1 000 255 9CH Green1 000 255 10CH Green Fine 1 000 255 11CH Blue1 000 255 12CH Blue Fine 1 000 255 13CH Wh...

Page 22: ...Yellow Red full Green full Blue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue...

Page 23: ...mber before shipping the product Be prepared to provide the model number serial number and a brief description of the Claim s for the return Clearly label the package with an RMA number Rasha will ref...

Page 24: ...t com UNITED STATES Rasha Professional A S LLC General Information Address 1800 Rustin Ave Riverside CA 92507 Technical Support Email support rashaprofessional com Voice 1 951 394 8480 1 951 654 3585...