background image

10

If you have a really old DCC system, you may find that this locomotive won’t work at 

all – nor will many other new models. Go update DCC your system to a newer version. 

Your computer is updated regularly. Your DCC system should be updated as well.

If your sounds do not operate correctly on a Digitrax DCC system, this likely means that 

you need to clear the memory on your system, achieved by “clearing slot #36.” A basic 

summary of how to do this can be found on the F40PH-2D page in the Support section 

of our web site. More detailed information can be found on the Digitrax web site.

TURN ON THE SOUND

Press F8 and you will hear the F40PH-2D startup sequence followed by the sound of 

it idling. You can adjust CVs to prevent the locomotive from running until the startup 

sequence has played out. Jason is really impatient so he turned this feature off. Refer to 

a full ESU LokSound Select decoder manual for more information. You can download it 

from our web site. It’s called the “Prime Mover Startup Delay” and at the time of writing 

it was on page 35.

If you press F8 when the locomotive is already moving, it will skip the startup and the 

sound will just turn on. Press F8 again to turn the sound off. 

Note that if you are listening to your F40PH-2D idling nicely and then you select another 

engine, your locomotive still thinks F8 is pressed so it will keep idling along. However, 

if someone else selects your locomotive’s number and F8 isn’t pressed on his or her con-

troller, the F40PH-2D will promptly shut down. He or she will need to press F8 again. 

We’re being gender neutral even though we know that just about everyone who bought 

this model is a man. Though we have it on good authority that one of the locomotives 

was purchased for a precocious schnoodle in Medicine Hat, so we should probably say 

“he, she or it.”

FUNCTIONS

F0  Headlights 

F11  Fast Doppler Horn 

F1  Bell 

F12  Hostler (Switching) Mode

F2  Horn (and Bell) 

F15  Emergency Horn

F3  Slow Doppler Horn 

F19  Turn Off Number Boards

F4  Full Throttle 

F23  Brake Release On/Off

F5  Turn On/Off HEP 

F24  Brake

F6  Ditch Lights

F7  Dim the Headlights

F8 Startup/Mute/Shutdown

F9  Strobe Light

F10  Xenon Light

Summary of Contents for F40PH-2D

Page 1: ...Rebuild OPERATOR S MANUAL FRAN AIS AU VERSO...

Page 2: ...nne of thought into this rebuilt F40PH 2D model and we hope you enjoy it That being said there is always the possibility that you ve found something wrong with your locomotive Maybe a grab iron has co...

Page 3: ...e Sound 10 Functions 10 Functions More Information 11 Horns 13 Sound Volume Settings 13 Sound Volume Settings Chart 14 Factory Reset 14 Awesome Slow Speed Thingy 14 More Information 15 Limited Lifetim...

Page 4: ...nto place before placing on the track Check that all underbody piping and appliances are firmly installed and clear of the track Of particular note are the air hoses on the ends of the locomotive and...

Page 5: ...on the molecular pattern of your locomotive If some thing pops off while you are removing the shell our starship s transporters will automatically lock on to the little part and beam it directly into...

Page 6: ...ontains an ESU designed motherboard which is connected to the track motor and lighting outputs A blind plug is attached to the motherboard using a 21 pin connector To install a decoder remove the blin...

Page 7: ...t Some throttle manufacturers produce special doo dads which are meant to trigger the sounds in locomotives on DC layouts As we have no involvement in the development of those doo dads we have absolut...

Page 8: ...consist the HEP would not be on in one of them as there are only two HEP circuits in a train Essentially the only time you would shut down the CAT engine is when you are about to enter Montreal s Cen...

Page 9: ...correctly to alert shop crews of this fact I wish I had known that BEFORE specifying the model features In the summer the shutdown method makes no difference but in the winter if an engine with Hotsta...

Page 10: ...the Prime Mover Startup Delay and at the time of writing it was on page 35 If you press F8 when the locomotive is already moving it will skip the startup and the sound will just turn on Press F8 again...

Page 11: ...bunch of other places It s worth downloading a copy of the Cana dian Rail Operating Rules Use The Google F3 Slow Doppler Horn We re really proud of this It s a K3L horn going past a level crossing at...

Page 12: ...ine incorrectly Please refer to the PROTOTYPICAL OPERATION DCC SOUND section above F10 Xenon Light This should be turned on any time you are running on the mainline and turned off well before you dim...

Page 13: ...are and what sounds great in one layout environment may sound too loud or too soft in another Fortunately all sound levels can be easily adjusted to best suit your own requirements and we recommend t...

Page 14: ...LER HORN VOLUME 411 128 0 128 ENGINE BRAKE VOLUME 419 85 0 128 RANDOM SOUND VOLUME 451 64 0 128 BRAKE SQUEAL VOLUME 459 128 0 128 FACTORY RESET On your F40PH 2D you perform a factory reset by entering...

Page 15: ...d Select decoder manual This is available on the F40PH 2D page in the Support section of our web site LIMITED LIFETIME WARRANTY We will do our best to solve any problems or issues that you may have wi...

Page 16: ...ut Yes even if it was your fault we will try our best to fix your locomotive for you Don t be shy ACKNOWLEDGEMENTS We turned to our core group of experts yet again for making this model so amazing Tha...

Reviews: