XG555 CANbus to DeviceNet Transducer Gateway   

April 21, 2005 

 

Product Specification for CANbus to DeviceNet 

Transducer Gateway 

 

 

The XG555 CANbus to DeviceNet Temposonics Gateway gathers position information from as many as 
four Temposonics CANBUS transducers, each with multiple magnets. This information is provided to a 
host over a DeviceNet interface. Setup information is stored on the local flash disk. The system is 
comprised of an embedded industrial computer, with a PC-104 stack providing hardware interfaces. The 
PC-104 stack includes the processor, a CANBUS interface, and a DeviceNet interface.

 

 

Features 

• 

Up to eight channels of MTS Temposonics CANBUS position information 

• 

Up to 15 magnets per transducer 

• 

DeviceNet interface 

• 

Full transducer resolution is provided  

• 

Non-volatile flash storage of setup data 

• 

Watchdog timer for reset upon software failure 

• 

Convenient screw terminal connections 

Specifications 

• 

Eight channels of 24 bit magnetostrictive transducer measurement via CANbus using MTS protocol 

• 

Device Net slave interface 

• 

Intel 80386 processor 

• 

Maximum 1 ms DeviceNet interface response time 

• 

Linear interpolation of transducer linearization data 

• 

4Mbytes of non-volatile flash storage 

• 

Power requirements: + 24V  

• 

Enclosure is 14 x 10 in 
 

Summary of Contents for XG555

Page 1: ...104 stack includes the processor a CANBUS interface and a DeviceNet interface Features Up to eight channels of MTS Temposonics CANBUS position information Up to 15 magnets per transducer DeviceNet int...

Page 2: ...5 Remote File Operations 6 Program Upgrades 6 Backup and Restore 7 ling and Changing Transducer Node IDs 7 Hardware 8 Processor 8 PC 104 boards 8 CANbus interface modules 8 CANBus 9 CANBus Connections...

Page 3: ...Pressing the enter key while viewing this status screen takes you to the setup menu Setup Setup can be accomplished via a terminal attached to the RS232 serial port of the XG555 or by using the displ...

Page 4: ...serial connector If the operator desires to enter the Setup Mode the operator should type three characters rapidly at 9600 baud until the control acknowledges with a setup menu The control is then in...

Page 5: ...h disk Display magnet positions Prints the position of a selected magnet until Q is pressed Pressing and 0 3 changes the selected magnet and transducer increments the selected magnet number will decre...

Page 6: ...e requested transducer Each bit of the status data corresponds to a magnet For example bit 0 of byte 60 indicates the status of magnet 0 on transducer 0 Byte 62 The consumed command byte The position...

Page 7: ...transducers A single transducer does not respond Check that the transducer has the right setup information entered and that the drop cable from the trunk to the transducer is ok You may need to use th...

Page 8: ...ator For COMM and ProComm press the PGUP key and select XMODEM For HyperTerminal select the Transfer pull down menu Once the XMODEM function has started you will see transfer status information printe...

Page 9: ...MSERV REMDISK or by using TRANSFER COMM Detect Utility Changing Transducer Serial Numbers Node IDs or baud rates Transducer serial Numbers Node Ids and Baud Rates can be detected and changed using the...

Page 10: ...Aim104 CAN module is an 8 bit PC 104 module providing a single channel optically isolated CAN bus interface In addition the board is fitted with an EEPROM for configuration information and an output p...

Page 11: ...or If they are to be powered from another 24V source then connect the power supply to the V pin on the Gateway and leave the V pin unconnected CANBus Termination For proper operation the CANBus cable...

Page 12: ...onnected to the 5 pin screw terminal In normal operation this is a separate supply from the CANBus transducer supply DeviceNet Termination For proper operation the DeviceNet cable must be terminated w...

Page 13: ...ril 21 2005 Serial Interface Cable Pinout The serial cable for use with REMSERV REMDISK or TRANSFER COMM is as follows RTS TX RX DSR RTS GND TX CTS RX PC DB9F 5 9 4 8 3 7 2 6 1 GND DTR DTR SAPPI DB9F...

Page 14: ...NET 1 2 3 4 5 24V CAN BUS 1 2 3 4 5 CANL 24V RET DEV TERM 120 120 24V 24V RET MTS CAN XDCR MTS D6 1 2 3 4 5 6 CANL POWER SUPPLY CANH 24V PWR 1 2 CANL CANH 24V SHIELD INSTALL TERMINATION AT LAST XDCR D...

Page 15: ...XG555 CAN to DeviceNet Gateway 13 April 21 2005 XG555 TOP COVER 9 1 9 9 5 8 3 3 8 4 1 5 TITLE XG555 GATEWAY Dimensions...

Reviews: