?-RPM models are capable of operating with Start/Stop and PWM transducers. The SAB-QS-?-SSI
models are capable of operating with SSI transducers.
8.
Transducer Setup
A.
Transducer Type
If you are using a PWM transducer, you must change the transducer type to PWM. If you are
using a SSI or Start/Stop transducer, choose RPM as the transducer type.
B.
Recirculations
The number of recirculations determines the worth of each count. A higher number of
recirculations increases the resolution of the counts but increases the update time. The
approximate value of a count can be determined through the following formula: (0.002
÷
recirculations) inches per count. Recirculations only need to be set when using a Start/Stop
transducer; otherwise, set the recirculations to 1.
9.
Further Setup
Some material related to setup of the SAB-QS is not covered in this guide. For more information on
advanced setup, see the SAB-QS manual.