SAB-QS Quick Start

5 of 5

November 9, 2000

Rapid Controls Inc.

Box 8390 

§

 Rapid City, SD 

§

 57709

Phone: 605-348-7688 

§

 Fax: 605-341-5496

http://www.rapidcontrols.com/ 

§

 email: [email protected]

?-RPM models are capable of operating with Start/Stop and PWM transducers. The SAB-QS-?-SSI
models are capable of operating with SSI transducers.

8.

 

Transducer Setup
A.

 

Transducer Type

If you are using a PWM transducer, you must change the transducer type to PWM. If you are
using a SSI or Start/Stop transducer, choose RPM as the transducer type.

B.

 

Recirculations

The number of recirculations determines the worth of each count. A higher number of
recirculations increases the resolution of the counts but increases the update time. The
approximate value of a count can be determined through the following formula: (0.002 

÷

recirculations) inches per count. Recirculations only need to be set when using a Start/Stop
transducer; otherwise, set the recirculations to 1.

9.

 

Further Setup

Some material related to setup of the SAB-QS is not covered in this guide. For more information on
advanced setup, see the SAB-QS manual.