AH-16-02.1
29
RansFlex Applicators
-
MAINTENANCE
Fluid Nozzle Removal
1. Insert 80353-00 wrench onto nozzle flats.
2. Insert O-ring, replace as required.
3. Install fluid nozzle using 80353-00 wrench.
Tighten till nozzle seats on O-ring and then 1/8
additional turn.
W A R N I N G
!
Prior to removing the fluid nozzle, all pres-
sure from the system must be relieved.
2. Clean and replace as necessary.
3. Install in reverse order.
Barrel Removal
1. Remove trigger.
NOTE
Do not over tighten. Fan pattern reduction will
be effected