AH-16-02.1
28
RansFlex Applicators
-
MAINTENANCE
• Straighten the applicator electrode if necessary.
• Clean the fluid filter, if used.
Daily (or at start of each shift)
• Verify that ALL solvent safety containers are
grounded!
• Check within 6m (20-ft.) of the point of operation
(of the applicator) and remove or ground ALL
loose or ungrounded objects.
• Inspect work holders for accumulated coating
materials (and remove such accumulations).
• Check that atomizer assembly is clean and
undamaged.
.5 M
W
NOTE
Standard electrode is "snap back" spray
wire electrode.
Air Cap Removal
1. Remove retaining ring and air cap.
W A R N I N G
!
It is the end users responsibility to insure the
.5 M
W
to ground condition is met.
Bi-Yearly
• Check air hose resistance. If resistance is greater
than .5 M
W
the hose should be replaced.
• On quick disconnect units check qd function. If
worn replace hose assembly.