SPECIFICATIONS
Operating
Temperature:
0
°
C to 50
°
C
Storage
Temperature:
-20
°
C to 85
°
C
Humidity:
0 to 95% non-condensing
Size:
20" H x 16" W x 8" D
(50.8 cm X 40.6 cm X 20.3 cm)
Weight:
52 lbs. (23.6 kg)
Electrical
AC Input:
A11515-XX0XX Models
100-120 VAC, 50/60 Hz
2.1 A rms
Fused at 3 Amps
A11515-XX1XX Models
200-240 VAC, 50/60 Hz
1.1 A rms
Fused at 1.5 Amps
Analog Inputs:
Remote Speed Setpoint
0-10 VDC or 4-20mA
Switch Selectable
Temp./Humidity Inputs
4-20mA
250 ft. (76.2m) maximum
cable length
Analog Outputs:
Speed Feedback
0-10 VDC or 4-20mA
Switch Selectable
Discreet Inputs:
Master Enable, Master
Reset, Rotator Enable
Sourced 24 VDC @ 2.3mA
Active Low - connect input
to ground to activate
Discreet
Outputs:
Temperature/Humidity,
Master Overspeed, Master
Underspeed, Master Loss
of Feedback, Master Fault,
Rotator Active, Rotator
Fault, Brake Control Active
High - put out 24 VDC when
active, 0.25A maximum per
output
Pneumatic
Inputs
Supply Air:
1/4" ID x 3/8" OD
110 psi (7.6 bar) maximum,
operating
80 psi (5.5 bar) minimum,
operating
40 micron filtration
Pressure Switches
(Enable Inputs):
15 psi (1.03 bar) minimum
to
activate
150 psi (10.3 bar) maximum
Outputs
Control Outputs*:
0.106" ID by 5/32" OD
100 ft. (30.5m) maximum
length to volume booster
Brake Control*:
0.170" ID x 1/4" OD
100 ft. (30.5m) maximum
length to brake valve
assembly
Brake Supply*:
1/4" ID x 3/8" OD
100 psi maximum
100 ft. (30.5m) maximum
length from brake valve
assembly
to
rotator
General
Fiber Optic
Cable:
Maximum length is 150 ft.
(45.7m)
Temperature / Humidity Probe
Temperature
Range:
0-100
°
C (32-212
°
F)
Accuracy:
± 0.6
°
C (± 1
°
F)
Repeatability:
± 0.3
°
C (± 0.5
°
F)
Humidity
Range:
3-95% RH
Accuracy (@ 72
°
F):
± 2.5% from 20% to 80%
± 3.1% <20%, >80%
Drift:
± 0.1% /
°
F
Repeatability:
± 1% RH
* Longer tubing lengths may be acceptable de-
pending on overall total lengths of pilot signals
and supply signals and the specific application.
However, longer lengths may degrade overall
speed control performance.
Environmental / Physical
Summary of Contents for Pulsetrack 2
Page 13: ...Figure 1 Typical Turbodisk 2 Installation With Temperature Humidity Cards...
Page 21: ...Figure 6 Electrical I O Breakout Terminal Locations...
Page 22: ...Figure 7 Control Panel Schematic...
Page 49: ...PARTS IDENTIFICATION Figure 17 Control Panel Front View...
Page 51: ...Figure 18 Control Panel Inside Door View...