pneumatic pressure signal by the I/P transducer.
The pneumatic signal is then supplied to a 1:1 air
piloted regulator (volume booster) located near
the atomizer.
Fiber Optic Receiver Module
A fiber optic transmitter assembly, located on each
atomizer, sends pulses of light through a fiber optic
cable to the Fiber Optic Receiver Module. The
Fiber Optic Receiver Module converts the light
pulses to an electrical signal which is then sent
to the Control card for processing.
Brake Solenoids (Optional)
Brake solenoids supply pilot air to the brake valves
in order to minimize the time required for transitions
from higher speeds to lower speeds. Braking is
not used on Turbodisk rotators.
Brake Air Valves (Optional)
The brake air valve is an air piloted three way
valve that supplies the necessary volume across
the rotator motor vanes in reverse direction to
produce quick reduction in speed. Brake valves
are not used for Turbodisk rotators.
Number of Temperature/Humidity Cards:
0, 1, 2, 3, 4, or 5
Model No. A11515 - A B C D E
Number of Atomizer Cards (Rotators):
0, 1, 2, 3, 4, 5, or 6
115 or 230 VAC Input:
0 - 115 VAC
1 - 230 VAC
Rotator Type:
0 - No rotator
6 - 10" unidisk
1 - 6" conical disk
7 - 12" unidisk / 12" conical
2 - Standard Aerobell disk
3 - Aerobell 33
8 - Standard Aerobell w/brake
4 - 6" unidisk
option
5 - 8" unidisk / 9 - Aerobell
33 w/brake option
9" conical disk
Cable/Tubing Length:
0 - None
3 - 75 ft. (22.86 m)
1 - 25 ft. (7.62 m) 4 - 100 ft. (30.48 m)
2 - 50 ft. (15.24 m)
When ordering, use A11515-ABCDE:
A11515 PULSETRACK 2 SPEED CONTROL AND
MONITOR SYSTEM MODEL IDENTIFICATION
Summary of Contents for Pulsetrack 2
Page 13: ...Figure 1 Typical Turbodisk 2 Installation With Temperature Humidity Cards...
Page 21: ...Figure 6 Electrical I O Breakout Terminal Locations...
Page 22: ...Figure 7 Control Panel Schematic...
Page 49: ...PARTS IDENTIFICATION Figure 17 Control Panel Front View...
Page 51: ...Figure 18 Control Panel Inside Door View...