GENERAL INFORMATION
The displacement pump (Gear Pump) is used on the RCS and RCS-2 systems. Pumps are
mounting directly to either a resin manifold (for the flushable pump unit) or a catalyst
manifold (for the non-flushable pump). Typical torque applied to the mounting bolts should
not exceed 17 lb-ft (23 N-m). Excessive torque can lead to pump seizure and internal
pump damage. Always follow specified torque settings.
INSTALLATION
RCS RESIN PUMP MOUNTED ILLUSTRATION
- MAX TORQUE FOR MOUNTING BOLTS: 17 LB-FT ( 23 N-m) -
Note:
TORQUE REQUIREMENTS AND TIGHTENING
PROCEDURES HAVE THE SAME TORQUE
SPECIFICATIONS FOR BOTH CATALYST
(NON-FLUSHABLE) AND RESIN (FLUSHABLE)
PUMPS.
CAREFULLY TIGHTEN BOLTS DOWN IN
AN “X” PATTERN AS SHOWN IN ABOVE
ILLUSTRATION
Both Series of Gear Pumps
Require Four Bolts:
•
Two SHCS (longest) bolts
use bushing A12304-XX
•
Two bolts (shorter) are
standard SHCS
System Start-Up
Pump assemblies are shipped with Wet-sol materi-
al to protect pump inner workings. To remove Wet-
sol, flush and purge the system with solvent as
needed.