9040 Low Voltage Control Unit Kit- Safety
AREA
HAZARD
SAFEGUARDS
Tells where hazards
Tells what the hazard is.
Tells how to avoid the hazard.
may occur.
Spray Area
Fire Hazard
Fire extinguishing equipment must be present in the
spray area and tested periodically.
Improper or inadequate operation
and maintenance procedures will Spray areas must be kept clean to prevent the
cause a fire hazard.
accumulation of combustible residues.
Protection against inadvertent
Smoking must never be allowed in the spray area.
arcing that is capable of causing
fire or explosion is lost if any
The high voltage supplied to the atomizer must be
safety interlocks are disabled
turned off prior to cleaning, flushing or maintenance.
during operation. Frequent power
supply shutdown indicates a
When using solvents for cleaning:
problem in the system requiring
correction.
Those used for equipment flushing should have flash
points equal to or higher than those of the coating
material.
Those used for general cleaning must have flash
points above 100
o
F (37.8
o
C).
Spray booth ventilation must be kept at the rates
required by European Norms, NFPA-33, OSHA,
and local or international codes.
In addition, ventilation must be maintained during
cleaning operations using flammable or combustible
solvents.
Electrostatic arcing must be prevented.
Test only in areas free of combustible material.
Testing may require high voltage to be on, but only
as instructed.
Non-factory replacement parts or unauthorized
equipment modifications may cause fire or injury.
If used, the key switch bypass is intended for use
only during set-up operations. Production should
never be done with safety interlocks disabled.
Never use equipment intended for use in waterborne
installations to spray solvent based materials.
The paint process and equipment should be set up
and operated in accordance with European Norms,
NFPA-33 or OSHA requirements.
CP-11-01
2
Summary of Contents for 9040
Page 2: ...CP 11 01...
Page 29: ...9040 Low Voltage Control Unit Kit Operation NOTES CP 11 01 26...
Page 33: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 30...
Page 41: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 38...
Page 44: ...CP 11 01 40...
Page 49: ...Models and specifications subject to change without notice 07 11...