9040 Low Voltage Control Unit Kit- Operation
OPERATION
!
W A R N I N G
>
The user MUST read and be familiar
with the SAFETY PRECAUTIONS and
SAFETY SECTIONS of this manual and
the Ransburg safety literature therein
identified BEFORE OPERATING the 9040
Cascade control unit.
!
W A R N I N G
>
The electrical discharge that is available
from the charging electrode of the
applicator must not exceed 0.25 mJ of
energy. To achieve this limit, any flow of
energy from the paint supply through the
paint line to the applicator electrode must
be prevented by grounding the paint line at
the applicator handle or body.
>
Verify that the applicator is actually
grounded before operating it! (See the
appropriate applicator manual.) If improper
readings are obtained, check that the
control unit is grounded. (See “Ground
Test Procedures” in the “Maintenance -
Troubleshooting” section of this manual.)
Figure 9: Operating Controls
Item Description
Item Description
1
Kilovolt Meter
5
AC Power On-Off Switch
2
AC Power Indicator
6
High Voltage Adjust Knob
3
High Voltage On Indicator
7
Cable Fault/hook OFF Indicator
4
Microamp Meter
8
Overload Indicator and Reset Switch
23
CP-11-01