4
2.0. DIAPHRAGM PUMP TECHNICAL DATA
1/2
’’
PVDF PUMP
Description
Unit
Value
Pump Type
Inch
1/2’’ PVDF
Max. fluid working pressure
Bar, Psi
7 (0,7 Mpa, 105 Psi)
Air feeding pressure range
Bar
1- 7
Max. Air consumption
m
3
/minute
0,5
Fluid per cycle
lt/cycle
0,125
Max. Head (for water viscosity)
m
60
Max. Suction depth
m
5
Max. Particle allowance
mm
1,5
Noise power level (at 5 bar)
dBA
74
Max. Capacity
lt/minute
60
Max. Cycle per minute
Cycles/minute 336
Max. Fluid temperature
⁰
C
80
⁰
C
Min. environment temp.
⁰
C
5
⁰
C
Max. environment temp.
⁰
C
40
⁰
C
Air inlet
Inch
1/4”
Air outlet
Inch
1/2”
Fluid inlet
Inch
1/2”
Fluid outlet
Inch
1/2”
Pump housing material
PVDF
Pump diaphragm material
Weight
kg
3.5
Package Dimensions /Weight
cm / g
16x21x32 / 300
2.1. D
ıaphragm runnıng temperature data
Diaphragm
Material
Temperature limits
BUNA-N
-12,2
⁰
C
65,6
⁰
C
PTFE (teflon)
4
⁰
C
104,4
⁰
C
Santoprene
-28,9
⁰
C
104,4
⁰
C
Polyurethane
-12,2
⁰
C
65,6
⁰
C
VİTON
-40
⁰
C
176,7
⁰
C
Neoprene
-17,8
⁰
C
93,3
⁰
C
EPDM
-51,1
⁰
C
137,8
⁰
C
3.0. DIAPHRAGM PUMP DEFINITION
This diaphragm pump works by using compressed air coming from a compressor. Pump
working principle is shown in the illustration below.
There are two valves distributing air in the pump. Outer valve is distributing the air to the
diaphragms.
Inner air valve is rotating the outer valve.
Running a pump fast does not always mean working it most productively. If a pump
works at highest capacity continuously, it will have diaphragm and valve problems
sooner. It is advisable to choose a higher capacity pump and it should not be used at
maximum pressure for long periods.
Diaphragm pump is mounted on the ground or on a tripod from its legs with bolts.
Air operated diaphragm pumps are suitable for transferring fluids up to 50,000 cP viscosity.