![Rankam TF21330 Series Assembly, Use And Care Manual Download Page 7](http://html1.mh-extra.com/html/rankam/tf21330-series/tf21330-series_assembly-use-and-care-manual_3661633007.webp)
TF2133002-RG-00 ENG Page 7 of 17 20160608-Ver.1
Lighting Instructions
Do not lean over LP cooker while lighting.
1
Read all instructions before lighting.
2
Turn regulator control valve to OFF position.
3
Fully turn timer control knob clockwise.
4
Fully open LP bottle valve.
5
Light match and place it over burner. PRESS
and HOLD push button of safety valve. Slowly
turn ON the regulator control valve. DO NOT
stand with head or arms over cooker.
6
When burner is lit, still HOLD the push button
for 10 seconds and then release.
7
If ignition does not occur in 5 seconds, turn the
burner control(s) off, wait 5 minutes, and repeat the lighting procedure.
Note: Cycle time for timer is around 15 minutes. If the timer is not reset within around 15 minutes, the burner will shut
OFF automatically. If this occurs, please follow lighting instructions and continue to cook.
CAUTION
If burner does not light OR if burner flame is accidentally extinguished, turn knob to OFF, wait 5 minutes, try again. If
the burner does not ignite with valve open OR if burner flame is accidentally extinguished after lighting, gas will
continue to flow out of the burner and could accidentally ignite with risk of injury.
Burner Flame Check
Light burner, rotate regulator knob from HIGH to LOW. You
should see a smaller flame in LOW position than seen on
HIGH. Always check flame prior to each use. The air
damper (D) mounted on the back of your burner helps to
control the amount of primary air that mixes with the LP
gas. A blue flame with little or no yellow flame provides the
best heat. Adjust the air damper by turning it clockwise or
counterclockwise until the desired flame is achieved.
Turning LP Cooker Off
Turn all knobs to OFF position, Turn LP tank OFF by turning OPD hand wheel clockwise to a full stop.
Hose Check
Before each use, check to see if there is evidence of abrasion, wear, cuts or leaks, the hose must be replaced
prior to the appliance being put into operation. The replacement hose assembly shall be that specified by the
manufacturer.
Cleaning the Burner
CAUTION
Checking and cleaning burner / venture tubes for insect nests. A clogged tube can lead to fire beneath the
appliances.
Spiders’ nests or wasps’ mud inside the burner may cause fire at the air damper. If a fire occurs, immediately turn off
gas supply at LP tank valve.
Note
:
Spiders and small insects can spin webs and build nests inside the burner. This especially occurs in late summer and
fall before frost when spiders are most active. These nests can obstruct gas flow and cause a fire in and around the
burner and orifice. Such a fire can
cause operator injury and serious damage to the appliance.
To help prevent a blockage and ensure full heat output, clean and inspect burner tube often (once or twice a month). NOTE: Water
or air pressure will not normally clear a spider web.