R80EX Tire Changer
22
P/N 5900087 — Rev. B — Jan. 2020
Connecting to Pressurized Air
The Tire Changer requires a 15 to 25 CFM Air Source with an operating air pressure of 140 to 165 PSI
/ 9.6 to 11.4 BAR.
Important
: The Tire Changer uses pneumatic and electrical energy; if your organization has
Lockout/Tagout policies, implement them once the unit is connected to the air source.
The air lines going out of the Regulator/Filter and Lubricator come connected and ready for use;
no
installation or adjustment is required when you receive the Tire Changer
.
The incoming air source connects to the Tire Changer via the Air In connector on the Regulator/Filter.
You need to provide a fitting for the Air In connector; it is not supplied.
Drawing not necessarily to scale. Not all components shown.
The following drawing shows a quick-connect air fitting that connects to the Air In connector. The
quick-connect air fitting is
not
supplied with the Tire Changer.
The
Regulator / Filter
controls the air pressure coming into the Tire Changer and removes
contaminants from the incoming air. It includes a gauge that shows the air pressure of the incoming
air. If you see water in the Water Sight Gauge, you can drain it using the Water Drain Plug. Refer to
The
Lubricator
puts pneumatic oil, for lubrication, into the incoming air that reaches it. This
lubricated air is routed to pneumatic components of the Tire Changer.