EN
1
16
USE
Control panel
L
T1
S1
Button Function
Led
Turns the lights ON/OFF at maximum
intensity.
-
L
Press and hold the button for approximately 4
seconds, with all the loads turned off (Motor
and Lights), to turn the Activated Charcoal
Filter alarm on/off.
LED
S1
flashes twice = alarm
ON.
LED
S1
flashes once = alarm
OFF.
Turns the motor on/off at speed one.
-
T1
Press and hold the button for approximately 2
seconds, with all the loads turned off (Motor
and Lights), to reset the Activated Charcoal
Filter alarm.
LED
S1
turns OFF (Fixed or
Flashing).
Signals the Metal Grease Filter saturation
alarm, indicating that it is necessary to wash the
filters. The alarm is triggered after the Hood
has been in operation for 100 working hours.
Fixed.
S1
When this is activated, it signals the Activated
Charcoal Filter saturation alarm, indicating that
the filter must be changed; the Metal Grease
Filters must also be washed. The Activated
Charcoal Filter saturation alarm comes into
operation after the Hood has been working for
200 hours.
Flashing.