MOUNT THE PLATE

Mount the plate of the electrical system
attaching it with 3 screws.

PLATE OF

THE

ELECTRICAL

SYSTEM

WIRING

Note: This range hood must be properly
grounded. The unit should be installed by
a qualified electrician in accordance with
all applicable national and local electrical
codes.

GROUNDING INSTRUCTIONS
This appliance must be grounded. In the
event of an electrical short circuit, grounding
reduces the risk of electric shock by
providing an escape wire for the electric
current. This appliance is equipped with a
cord having a grounding wire with a
grounding plug. The plug must be plugged
into an outlet that is properly installed and
grounded.
WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely
understood, or if doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified
electrician install an outlet near the appliance.
Set the electrical power supply within the space covered by the decorative flues.
Position the power socket at a maximum distance of 33-7/16” (85 cm) from where
the lead exits from the hood (see illustration alongside). Make sure this does not
interfere with the bracket fastening area or with the decorative flue (where the flue
touches the wall).
Fit the plug into the power socket.

Summary of Contents for RM51000 Series

Page 1: ...eries Broan NuTone LLC 926 West State Street Hartford WI 53027 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 Broan NuTone Canada INC 1140 Tristar Drive Mississauga Ontario L5T 1H9 ENGLISH 3 FRAN A...

Page 2: ......

Page 3: ...lean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Useproperpansize Alwaysusecookwareappropriate for the size of the surface element WARNING TO REDUCE THE R...

Page 4: ...lar 1 Flue Mounting Bracket 8 Mounting Screws 4 8 x 38mm Pan Head 5 Mounting Screws 3 9 x 9 5mm Pan Head 8 Drywall Anchors 1 Installation Instructions MOUNTING BRACKET DISCHARGE COLLAR FLUE MOUNTING B...

Page 5: ...ble Larger ducting may be required for best performance with longer duct runs 4 Install a roof or wall cap Connect round metal ductwork to cap and work back to wards hood location Use duct tape to sea...

Page 6: ...plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not...

Page 7: ...d wall anchors to secure flue mounting bracket to the ceiling as shown 3 Use 6 round metal duct to connect the duct collar on the hood to the ductwork above 4 Use duct tape to make all joints secure a...

Page 8: ...Connect the non ducted recirculation plenum to the upper flue section with 4 flat head screws supplied 5 Install the reduction on the discharge collar 6 Measure the distance from the top of the reduct...

Page 9: ...aning tips Hot water with soap or detergent is all that is usually needed Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or de...

Page 10: ...requires two halogen bulbs Type T4 12V 20W ALWAYS SWITCH OFFTHE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ONTHE APPLIANCE To change bulbs 1 Loosen the ring nut by turning it counterclockw...

Page 11: ...ty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTIO...

Reviews: