OPERATION

Controls

The hood is operated using the slide controls
under the bottom of the hood.

The 

light switch

 turns the lamps on and off.

The 

blower  switch

 :makes it possible to

select the motor operating speed. Position 0:
motor off.

The 

pilot lamp

 lights up whenever the blower

is on.

LIGHT

SWITCH

PILOT

LAMP

BLOWER

SWITCH

HALOGEN BULBS

This range hood requires two halogen bulbs
(Type T4, 12V, 20W).

ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.

To change bulbs:

1. Loosen the ring nut by turning it

counterclockwise.

2. Remove the bulb by pulling sideward(DO

NOT ROTATE). 

CAUTION: BULB MAY BE

HOT!

3. Replace with Type T4, 12V, 20W halogen

bulb. Do not touch replacement bulb with
bare hands!

RING  NUT

FUSE REPLACEMENT

SWITCH OFF THE ELECTRICITY SUPPLY.

Remove the decorative flue.

Open the fuse box.

Replace with the same type of fuse (5x20mm,
4A, 125V).

FUSE
BOX

FUSE

DECORATIVE
FLUE

Summary of Contents for RM51000 Series

Page 1: ...eries Broan NuTone LLC 926 West State Street Hartford WI 53027 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 Broan NuTone Canada INC 1140 Tristar Drive Mississauga Ontario L5T 1H9 ENGLISH 3 FRAN A...

Page 2: ......

Page 3: ...lean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Useproperpansize Alwaysusecookwareappropriate for the size of the surface element WARNING TO REDUCE THE R...

Page 4: ...lar 1 Flue Mounting Bracket 8 Mounting Screws 4 8 x 38mm Pan Head 5 Mounting Screws 3 9 x 9 5mm Pan Head 8 Drywall Anchors 1 Installation Instructions MOUNTING BRACKET DISCHARGE COLLAR FLUE MOUNTING B...

Page 5: ...ble Larger ducting may be required for best performance with longer duct runs 4 Install a roof or wall cap Connect round metal ductwork to cap and work back to wards hood location Use duct tape to sea...

Page 6: ...plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not...

Page 7: ...d wall anchors to secure flue mounting bracket to the ceiling as shown 3 Use 6 round metal duct to connect the duct collar on the hood to the ductwork above 4 Use duct tape to make all joints secure a...

Page 8: ...Connect the non ducted recirculation plenum to the upper flue section with 4 flat head screws supplied 5 Install the reduction on the discharge collar 6 Measure the distance from the top of the reduct...

Page 9: ...aning tips Hot water with soap or detergent is all that is usually needed Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or de...

Page 10: ...requires two halogen bulbs Type T4 12V 20W ALWAYS SWITCH OFFTHE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ONTHE APPLIANCE To change bulbs 1 Loosen the ring nut by turning it counterclockw...

Page 11: ...ty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTIO...

Reviews: