background image

 

 

 

 

EN 

 

7

 

Mounting the hood body 

•  Open the ducting panels. 
•  Disconnect the panel from the hood canopy by slid-

ing the fixing pin lever.(A) 

•  Remove the metal grease filters by turning the han-

dles provided. 

•  Adjust the two screws Vr, on brackets 11a, to a mini-

mum.(B) 

•  Hook the hood canopy onto the two brackets 11a. 
•  From inside the hood canopy, adjust the screws Vr to 

set the Hood Canopy level. 

•  Tighten the safety screw 11

 

( A )

( B )

Vr

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to 
the chimney using either a flexible or rigid pipe ø 150 
or 125 mm, the choice of which is left to the installer. 
 
•  To install a ø 125 mm air exhaust connection, insert 

the reducer flange 9 on the hood body air outlet and 
the adapting ring ø120-125 10 on the reducer flange. 

•  Fix the pipe in position using sufficient pipe clamps 

(not supplied). 

•  Remove any activated charcoal filters.

 

 

9

ø 125

10

ø 150

RECYCLING VERSION AIR OUTLET 

To install the hood in recycling version, the optional 
charcoal filter kit must be purchased. 
 
•  Remove the chimney angle bracket. 
•  Screw the filter cover onto the air outlet, using four 

screws 12c (2.9 x 12.5). 

•  Fix the air outlet grid 8 on the recirculation air outlet 

using the 2 screws 12d (2,9 x 9,5) provided. 

 

16

12c

12d

8

Summary of Contents for GLX390

Page 1: ...GLX390 Hood Instructions Manual www rangemaster co uk...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 10...

Page 3: ...is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overhea...

Page 4: ...EN 4 4 CHARACTERISTICS Dimensions 1270 MIN 1390 MAX 1600 126 81...

Page 5: ...14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 1...

Page 6: ...sing a 12 mm drill bit Drill at the points 2 marked using a 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and screw into place Insert plug 11 into hole 2 To install a decorative chimney...

Page 7: ...himney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a 125 mm air exhaust connection insert the reducer flange 9 on the hood body air outl...

Page 8: ...imney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5...

Page 9: ...lls Can be enabled at any speed and is disabled by pressing the button T1 briefly T3 Speed on Third speed T4 Speed Fixed Max speed Flashing Intensive speed Suitable for the strongest cooking vapours a...

Page 10: ...control near to heat sources Used batteries must be disposed of in the proper manner Ducting panels Open the ducting panels Disconnect the panel from the hood canopy by sliding the fix ing pin lever C...

Page 11: ...washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation or more fre quently for particularly heavy usage Remove the filters one at a time holding them up with o...

Page 12: ...3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes twice Activated charcoal filter saturation alarm ENABLED LED flashes once Activated charcoal filter saturation alarm DISABLED...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...436004184_ver1 AGA RANGEMASTER LTD...