Activated charcoal filter (Recirculation version) 

The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes 
or at least every 4 months. The alarm signal will only light up when the extractor motor is 
switched on. 

Alarm signal activation 
•  In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or 

at a later date. Turn the Lights and the suction Motor off. 

•  Disconnect the Hood using the Main switch or the double-pole switch on the mains power 

supply. 

•  Restore the connection by pressing and holding T1
•  Release the button.  All five LEDs are turned on. 
•  Within 3 seconds press T1 until LEDs  T1 and T4 flash in confirmation: 
  -  LED flashes twice - Activated charcoal filter saturation alarm ENABLED
  -  LED flashes once - Activated charcoal filter saturation alarm DISABLED

 

REPLACING THE ACTIVATED CHARCOAL FILTER 

Alarm signal reset 
•  Switch off the lights and extractor motor. 
• Press button T3 for at least 3 seconds, until the leds start to 

flash. 

Replacing the Filter 
•  Remove the metal grease filters 
•  Remove the saturated activated carbon filters as shown (A). 
•  Fit the new filters (B). 
•  Replace the metal grease filters. 

 

A

B

 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 
•  Remove the light cover by unfastening the screws that hold it. 
•  Extract the lamp from the Support. 
•  Replace with another of the same type, making sure that the 

two pins are properly inserted in the lamp holder socket holes. 

•  Replace the light cover.

 

 

 

Summary of Contents for GLX390

Page 1: ...GLX390 Hood Instructions Manual www rangemaster co uk...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 10...

Page 3: ...is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overhea...

Page 4: ...EN 4 4 CHARACTERISTICS Dimensions 1270 MIN 1390 MAX 1600 126 81...

Page 5: ...14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 1...

Page 6: ...sing a 12 mm drill bit Drill at the points 2 marked using a 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and screw into place Insert plug 11 into hole 2 To install a decorative chimney...

Page 7: ...himney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a 125 mm air exhaust connection insert the reducer flange 9 on the hood body air outl...

Page 8: ...imney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5...

Page 9: ...lls Can be enabled at any speed and is disabled by pressing the button T1 briefly T3 Speed on Third speed T4 Speed Fixed Max speed Flashing Intensive speed Suitable for the strongest cooking vapours a...

Page 10: ...control near to heat sources Used batteries must be disposed of in the proper manner Ducting panels Open the ducting panels Disconnect the panel from the hood canopy by sliding the fix ing pin lever C...

Page 11: ...washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation or more fre quently for particularly heavy usage Remove the filters one at a time holding them up with o...

Page 12: ...3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes twice Activated charcoal filter saturation alarm ENABLED LED flashes once Activated charcoal filter saturation alarm DISABLED...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...436004184_ver1 AGA RANGEMASTER LTD...

Reviews: