![Rangemaster Classic 110 110 Dual Fuel FSD User'S Manual & Installation Instructions Download Page 29](http://html1.mh-extra.com/html/rangemaster/classic-110-110-dual-fuel-fsd/classic-110-110-dual-fuel-fsd_users-manual-and-installation-instructions_3690790029.webp)
27
10. Technical Data
The cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
Connections
Gas (Rp ½ at rear right-hand side)
Electric
Natural gas
20 mbar
220-240 V 50 Hz
Butane
29 mbar
Propane
37 mbar
(See the appliance badge for test pressures)
Dimensions
Overall height
minimum 900 mm
maximum 925 mm
Overall width
900 mm
Overall depth
650 mm
Refer to 'Positioning the Cooker'.
Ratings
Natural Gas 20 mb
L.P. Gas
Hotplate
Injector
Screw
Injector
Screw
Wok burner
3.65 kW
internal 80
96
3.5 kW (246 g/h)
internal 54
57
external 129
external 77
Large burner
3.0 kW
134
54
3.0 kW (210 g/h)
87
40
Medium burner
1.7 kW
109
39
1.7 kW 119 g/h)
68
32
Small burner
1.0 kW
75
38
1.0 kW (70 g/h)
51
28
Oven Efficiency
Ovens
Left-hand oven
Right-hand oven
Conventional
Forced air convection
Maximum output
2.2 kW
2.5 kW
Energy efficiency class on a scale
of A (more efficient) to G (less efficient)
A
A
Energy consumption based on standard load
0.99 kWh
0.85 kWh
Usable volume (litres)
67
67
Size
Large
Large
Time to cook standard load
40 minutes
38 minutes
Surface area of the grid
1400 cm
2
1400 cm
2
Grill
2.3 kW
Warmer
160 W
Maximum total electrical load at 230 V: 7.2 kW (approximate total including oven lights, oven fan, etc.)
ArtNo.105-0008 - Technical data - 90 induction - Elan