OWNER’S MANUAL
25
SIXTY-EIGHT
Control Change format is shown in the following tables.
Control Change Input to the Device:
Parameter Description
Control
Number
Values
PGM 1 Phono Sensitivity 21
Value
Sens. (mV)
dB
0
2.5
12.04
1
3
10.46
2
3.5
9.12
3
4
7.96
4
4.5
6.94
5 (Default)
5
6.02
6
5.5
5.19
7
6
4.44
8
6.5
3.74
9
7
3.10
10
7.5
2.5
11
8
1.94
12
8.5
1.41
13
9
0.92
14
9.5
0.45
15
10
0.00
PGM 1 Filter Resonance
22
0-64: Low
65-127: High
PGM 1 Record Select
23
1: Record PH/CD 1
2: Record PGM 1 Post
3: Record Aux 1
PGM 2 Phono Sensitivity 24
Same as PGM 1 Phono Sensitivity
PGM 2 Filter Resonance
25
0-64: Low
65-127: High
PGM 2 Record Select
26
1: Record PH/CD 2
2: Record PGM 2 Post
3: Record Aux 2
MIDI in
“Control Change” assignments for the driver control panels.
Control Change
35
34
21
22
23
24
25
26
27
28
29
30
31
32
33
36
37