Remote-Control Commands
R&S
®
SMCVB-K164
112
User Manual 1179.0974.02 ─ 02
[:SOURce<hw>]:BB:T2DVb:FEF:PAYLoad
<FEFPayload>
Sets the FEF payload.
Parameters:
<FEFPayload>
NULL | NOISe
NULL
I/Q values of the FEF payload are zeroes.
NOISe
I/Q values of the FEF payload are modulated in the frequency
domain using a PRBS and transformed into the time domain by
The technique allows generating payload with a power level
equal to the T2 frame.
*RST:
NULL
Example:
See
Example "Configuring network parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:FEF:TYPE
<FEFType>
Queries the type of the associated FEF part.
Parameters:
<FEFType>
integer
Range:
0 to 15
*RST:
0
Example:
See
Example "Configuring network parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:MISO:MODE?
group mode, that allows to set the MISO group of the modulator man-
ually.
Return values:
<GroupMode>
MANual
*RST:
MANual
Example:
See
Example "Configuring network parameters"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:MISO[:GROup]
<MisoGroup>