Signal Generator Settings
R&S
®
SGT100A
111
User Manual 1176.8674.02 ─ 07
Signal Duration Unit
Available only for "Trigger Mode > Single".
Defines the unit for the entry of the length of the signal sequence to be output.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit
Signal Duration
Available only for "Trigger Mode > Single".
Defines the length of the signal sequence to be output. The unit of the entry is defined
under "Signal Duration Unit". It is then possible to deliberately output just part of the
signal, an exact sequence of the signal, or a defined number of repetitions of the sig-
nal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth
Running/Stopped
Displays the status of signal generation.
"Running"
The waveform is output; a trigger was (internally or externally) initi-
ated in triggered mode.
If "Armed_Auto" or "Armed_Retrigger" have been selected, the gen-
eration of signals can be stopped with the "Arm" button. A new trigger
(internally with "Execute Trigger" or externally) causes a restart.
"Stopped"
The waveform output is stopped. The instrument waits for an internal
or external trigger event to restart. ARB modulation is disabled.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe?
Arm
Available only in the "Running mode" and for "Trigger Mode > Armed_Auto" or "Trigger
Mode > Armed_Retrigger".
Stops the waveform output.
Signal output can be restarted by a new trigger (internally with "Execute Trigger" or
externally).
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute
Execute Trigger
Executes the trigger manually. A manual trigger can be executed only when an internal
trigger source and a trigger mode other than "Auto" have been selected.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
Trigger Source
Selects trigger source.
"Internal"
The trigger event is executed by "Execute Trigger".
Baseband