Remote Control Commands
R&S
®
SGT100A
356
User Manual 1176.8674.02 ─ 07
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:DELay
........................................ 360
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:TDELay
.......................................360
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:RDELay?
.................................... 360
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:INHibit
........................................ 361
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence
......................................................... 361
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute
The command stops waveform output for trigger modes Armed_Auto and Armed_Ret-
rigger. A subsequent internal or external trigger event restart waveform output.
Example:
BB:ARB:TRIG:SOUR INT
sets internal triggering.
BB:ARB:TRIG:SEQ ARET
sets Armed_Retrigger mode, i.e. every trigger event causes
waveform output to restart.
BB:ARB:TRIG:EXEC
executes a trigger, waveform output is started.
BB:ARB:TRIG:ARM:EXEC
waveform output is stopped.
BB:ARB:TRIG:EXEC
executes a trigger, waveform output is started again.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
The command executes a trigger. The internal trigger source must be selected using
the command
ARB:TRIGger:SOURce INTernal
and a trigger mode other than
AUTO
must be selected using the command
:ARB:SEQuence
.
Example:
BB:ARB:TRIG:SOUR INT
sets internal triggering.
BB:ARB:SEQ RETR
sets Retrigger mode, i.e. every trigger event causes signal out-
put to restart.
BB:ARB:TRIG:EXEC
executes a trigger.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:SYNChronize:OUTPut
<Output>
(enabled for "Trigger Source" External)
Enables/disables output of the signal synchronous to the external trigger event.
SOURce Subsystem