background image

Basic Safety Instructions

R&S

®

FSH-Z114

6

User Manual 1321.2501.02 ─ 01

Transport

If you use the product in a vehicle, it is the sole responsibility of the driver to drive the vehicle
safely and properly. The manufacturer assumes no responsibility for accidents or collisions.
Never use the product in a moving vehicle if doing so could distract the driver of the vehicle.
Adequately secure the product in the vehicle to prevent injuries or other damage in the event
of an accident.

Waste disposal / environmental protection

Specially marked equipment has a battery or accumulator that must not be disposed of with
unsorted municipal waste, but must be collected separately. It may only be disposed of at a
suitable collection point or via a Rohde & Schwarz customer service center.

Waste electrical and electronic equipment must not be disposed of with unsorted municipal
waste, but must be collected separately.
Rohde & Schwarz GmbH & Co. KG has developed a disposal concept and takes full respon-
sibility for take-back obligations and disposal obligations for manufacturers within the EU.
Contact your Rohde & Schwarz customer service center for environmentally responsible dis-
posal of the product.

If products or their components are mechanically and/or thermally processed in a manner that
goes beyond their intended use, hazardous substances (heavy-metal dust such as lead, ber-
yllium, nickel) may be released. For this reason, the product may only be disassembled by
specially trained personnel. Improper disassembly may be hazardous to your health. National
waste disposal regulations must be observed.

If handling the product releases hazardous substances or fuels that must be disposed of in a
special way, e.g. coolants or engine oils that must be replenished regularly, the safety instruc-
tions of the manufacturer of the hazardous substances or fuels and the applicable regional
waste disposal regulations must be observed. Also observe the relevant safety instructions
in the product documentation. The improper disposal of hazardous substances or fuels can
cause health problems and lead to environmental damage.

For additional information about environmental protection, visit the Rohde & Schwarz website.

Summary of Contents for FSH-Z114

Page 1: ...R S FSH Z114 Precision Frequency Reference User Manual User Manual EI12 1321 2501 02 01 Test Measurement...

Page 2: ...4 2 User Manual 1321 2501 02 01 Contents 1 Basic Safety Instructions 3 2 Front View of R S FSH Z114 7 3 Operating the R S FSH Z114 8 3 1 Unpacking the R S FSH Z114 8 3 2 Using the R S FSH Z114 8 4 Abo...

Page 3: ...e if the product is used for any purpose other than its designated purpose or in disregard of the manufacturer s instructions The manufacturer shall assume no responsibility for such use of the produc...

Page 4: ...such as radiators or fan heaters The ambient temperature must not exceed the maximum temperature specified in the product documentation or in the data sheet Product overheating can cause electric shoc...

Page 5: ...tor must evaluate workplaces where there is a special risk of exposure to radiation and if nec essary take measures to avert the potential danger Should a fire occur the product may release hazardous...

Page 6: ...r take back obligations and disposal obligations for manufacturers within the EU Contact your Rohde Schwarz customer service center for environmentally responsible dis posal of the product If products...

Page 7: ...Z114 R S FSH Z114 7 User Manual 1321 2501 02 01 2 Front View of R S FSH Z114 This section describes the front view and connector details of R S FSH Z114 Fig 2 1 Front View 1 Connector cable 2 Precisio...

Page 8: ...pack aging The packaging contains the R S FSH Z114 together with the connector cable R S part number 1309 7407 00 3 2 Using the R S FSH Z114 The following section describes the steps to set up the R S...

Page 9: ...H After the R S FSH Z114 is connected to the R S FSH it is detected by the R S FSH by turning on the Auto Accessory Detection in the setup menu Selecting Auto Accessory Detection on the R S FSH 1 Pres...

Page 10: ...s name will be displayed at the top of the R S FSH screen The color of the label FSH Z114 turns green once the R S FSH Z114 is locked and ready to use Fig 3 3 R S FSH Z114 s status Operating the R S F...

Page 11: ...ENTER key Fig 3 4 Frequency Counter Selection The Label M at the upper left hand corner of the measurement diagram changes to C to indicate that the frequency counter has been switched on The resoluti...

Page 12: ...To make sure that the frequency counter works correctly the frequency span should not be wider than 630 resolution bandwidth Using remote control In remote control operation with the R S FSH Z114 opt...

Page 13: ...re version 2 12 or higher Supported Instrument Models Designation Type Order No Spectrum Analyzer 9 kHz to 3 6 GHz with preamplifier R S FSH4 1309 6000 04 Spectrum Analyzer 9 kHz to 3 6 GHz with pream...

Page 14: ...Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988...

Reviews: