Operating the products requires special training and intense concentration. Make sure that
persons who use the products are physically, mentally and emotionally fit enough to do so;
otherwise, injuries or material damage may occur. It is the responsibility of the employer/
operator to select suitable personnel for operating the products.

As with all industrially manufactured goods, the use of substances that induce an allergic
reaction (allergens) such as nickel cannot be generally excluded. If you develop an allergic
reaction (such as a skin rash, frequent sneezing, red eyes or respiratory difficulties) when
using a Rohde & Schwarz product, consult a physician immediately to determine the cause
and to prevent health problems or stress.

Before you start processing the product mechanically and/or thermally, or before you take it
apart, be sure to read and pay special attention to the section titled "Waste disposal/Envi-
ronmental protection", item 1.

Depending on the function, certain products such as RF radio equipment can produce an
elevated level of electromagnetic radiation. Considering that unborn babies require increased
protection, pregnant women must be protected by appropriate measures. Persons with pace-
makers may also be exposed to risks from electromagnetic radiation. The employer/operator
must evaluate workplaces where there is a special risk of exposure to radiation and, if nec-
essary, take measures to avert the potential danger.

Should a fire occur, the product may release hazardous substances (gases, fluids, etc.) that
can cause health problems. Therefore, suitable measures must be taken, e.g. protective
masks and protective clothing must be worn.

EMC classes (in line with CISPR 11)
Class A: Equipment suitable for use in all environments except residential environments and
environments that are directly connected to a low-voltage supply network that supplies resi-
dential buildings.
Class B: Equipment suitable for use in residential environments and environments that are
directly connected to a low-voltage supply network that supplies residential buildings.

Repair and service

The product may be opened only by authorized, specially trained personnel. Before any work
is performed on the product or before the product is opened, it must be disconnected from
the AC supply network. Otherwise, personnel will be exposed to the risk of an electric shock.

Adjustments, replacement of parts, maintenance and repair may be performed only by elec-
trical experts authorized by Rohde & Schwarz. Only original parts may be used for replacing
parts relevant to safety (e.g. power switches, power transformers, fuses). A safety test must
always be performed after parts relevant to safety have been replaced (visual inspection,
protective conductor test, insulation resistance measurement, leakage current measurement,
functional test). This helps ensure the continued safety of the product.

Summary of Contents for FSH-Z114

Page 1: ...R S FSH Z114 Precision Frequency Reference User Manual User Manual EI12 1321 2501 02 01 Test Measurement...

Page 2: ...4 2 User Manual 1321 2501 02 01 Contents 1 Basic Safety Instructions 3 2 Front View of R S FSH Z114 7 3 Operating the R S FSH Z114 8 3 1 Unpacking the R S FSH Z114 8 3 2 Using the R S FSH Z114 8 4 Abo...

Page 3: ...e if the product is used for any purpose other than its designated purpose or in disregard of the manufacturer s instructions The manufacturer shall assume no responsibility for such use of the produc...

Page 4: ...such as radiators or fan heaters The ambient temperature must not exceed the maximum temperature specified in the product documentation or in the data sheet Product overheating can cause electric shoc...

Page 5: ...tor must evaluate workplaces where there is a special risk of exposure to radiation and if nec essary take measures to avert the potential danger Should a fire occur the product may release hazardous...

Page 6: ...r take back obligations and disposal obligations for manufacturers within the EU Contact your Rohde Schwarz customer service center for environmentally responsible dis posal of the product If products...

Page 7: ...Z114 R S FSH Z114 7 User Manual 1321 2501 02 01 2 Front View of R S FSH Z114 This section describes the front view and connector details of R S FSH Z114 Fig 2 1 Front View 1 Connector cable 2 Precisio...

Page 8: ...pack aging The packaging contains the R S FSH Z114 together with the connector cable R S part number 1309 7407 00 3 2 Using the R S FSH Z114 The following section describes the steps to set up the R S...

Page 9: ...H After the R S FSH Z114 is connected to the R S FSH it is detected by the R S FSH by turning on the Auto Accessory Detection in the setup menu Selecting Auto Accessory Detection on the R S FSH 1 Pres...

Page 10: ...s name will be displayed at the top of the R S FSH screen The color of the label FSH Z114 turns green once the R S FSH Z114 is locked and ready to use Fig 3 3 R S FSH Z114 s status Operating the R S F...

Page 11: ...ENTER key Fig 3 4 Frequency Counter Selection The Label M at the upper left hand corner of the measurement diagram changes to C to indicate that the frequency counter has been switched on The resoluti...

Page 12: ...To make sure that the frequency counter works correctly the frequency span should not be wider than 630 resolution bandwidth Using remote control In remote control operation with the R S FSH Z114 opt...

Page 13: ...re version 2 12 or higher Supported Instrument Models Designation Type Order No Spectrum Analyzer 9 kHz to 3 6 GHz with preamplifier R S FSH4 1309 6000 04 Spectrum Analyzer 9 kHz to 3 6 GHz with pream...

Page 14: ...Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988...

Reviews: