1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
175
User Manual 1173.9511.02 ─ 11
<RevA>
Range:
5 to 127
*RST:
8+i for Pilot i=1,2,3
<RevB>
Range:
5 to 127
*RST:
8+i for Pilot i=1,2,3
Example:
See
Firmware/Software:
V1.0.15.0
V2.1.20: Dependency on pre-selected pilot; optional parameter
RevB added
Options:
Rev. B support (including multiple pilots) requires option R&S
CMW-KS881.
Manual operation:
See
"MAC Index [Rev. 0] / [Rev. A] / [Rev. B]"
2.6.6.7
Reverse Power Control
The following commands provide closed loop power control settings.
CONFigure:EVDO:SIGN<i>:RPControl:PCBits
..................................................................175
CONFigure:EVDO:SIGN<i>:RPControl:SSIZe
...................................................................176
CONFigure:EVDO:SIGN<i>:RPControl:REPetition
............................................................ 176
CONFigure:EVDO:SIGN<i>:RPControl:SEGMent<no>:BITS
.............................................. 176
CONFigure:EVDO:SIGN<i>:RPControl:SEGMent<no>:LENGth
..........................................177
CONFigure:EVDO:SIGN<i>:RPControl:RUN
.....................................................................177
CONFigure:EVDO:SIGN<i>:RPControl:PCBits
<PCBits>
Defines a power control bit pattern which the R&S
CMW transmits in order to control
the transmitter output power of the AT.
Parameters:
<PCBits>
AUTO | AUP | ADOWn | HOLD | PATTern
AUTO:
Active closed loop power control
AUP:
Power up bits
ADOW:
Power down bits
HOLD:
Alternating power up and power down bits
PATT
: Sends the user specific segment bits executed by
*RST:
AUTO
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V1.0.15.0
V3.2.80: added "PATT"
Options:
R&S CMW-K890 required for PATTern
Manual operation:
See
Command Reference