1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
176
User Manual 1173.9511.02 ─ 11
CONFigure:EVDO:SIGN<i>:RPControl:SSIZe
<SSize>
Gets/sets the power control step size, i.e. the nominal change in mean output power
per single power control bit.
Parameters:
<SSize>
Range:
0.5 dB to 1 dB
*RST:
1 dB
Default unit: dB
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RPControl:REPetition
<Repetition>
Specifies the repetition mode of the pattern execution.
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot
: the pattern execution is stopped after a single-shot
CONTinuous
: the pattern execution is repeated continuously
and stopped by the
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V3.2.80
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RPControl:SEGMent<no>:BITS
<SegmentBits>
Sets the user specific power control bits.
Suffix:
<no>
.
1..4
Segment number
Parameters:
<SegmentBits>
DOWN | UP | ALTernating
All 0, all 1 or alternating
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V3.2.80
Options:
R&S CMW-K890
Manual operation:
See
Command Reference