OM-PT-W-L SERIES PREP TABLES

INSTALLATION

CAUTION:  THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT.  USE CAUTION 

WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER.  

AVOID DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A 

LEAK. 

WARNING:  FAILURE TO FOLLOW INSTALLATION GUIDELINES AND 

RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.

WARNING:  IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. 

CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE 

FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON 

THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING 

VOLTAGE LIMITS WILL VOID THE WARRANTY.

 

THE  CAREL CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT 
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.

WARNING:  IT IS IMPORTANT THAT A VOLTAGE READING BE MADE AT THE COMPRESSOR 

MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION 

TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS 

BEING SUPPLIED.  LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT 
OPERATION AND THEREBY VOID ITS WARRANTY.

WARNING:  EVAPORATOR FANS RUN CONTINUOUSLY WHILE THE BASE IS POWERED ON.
WARNING:  THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL, 

INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE 

SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15. 

SELECTING A LOCATION FOR YOUR NEW UNIT

The following conditions should be considered when selecting a location for 
your unit:
1. 

Floor Load: 

 The area on which the unit will rest must be level, free of vibration, 

and suitably strong enough to support the combined weights of the unit plus 
the maximum product load weight. All casters must be in contact with the floor 
to support the weight. Casters may require shims in order for the caster to be 
in contact with the floor. NOTE:  If there is a question pertaining to weight load 
limits, consult the factory at 1-888-994-7636.

2. 

Clearances:

  Unit shall have a clearance of 0 inches at the top, 0 inches at 

the rear and 0 inches at each side.

3. 

Ventilation:

  The air cooled self contained unit requires a sufficient amount 

of cool clean air.  Avoid surrounding your unit around other heat generating 
equipment and out of direct sunlight.  Also, avoid locating in an unheated 
room or where the room temperature may drop below 70° F (21°C) or above 
86°F (32°C). Do not place any object that can block the ventilation exhaust 
from the machine compartment register.

INSTALLATION CHECKLIST

After the final location has been determined, refer to the following checklist prior 
to start-up:
1.  Check all exposed refrigeration lines to ensure that they are not kinked, 

dented, or rubbing together or rubbing against any steel.

2.  Check all visible components for any potential damage.
3.  Check that the condenser and evaporator fans rotate freely without striking 

any stationary members.

4.  Unit must be property leveled; Check all legs or casters ensure they all are 

in contact with the floor while maintaining a level work surface.  Adjusting 
bullet feet height or shimming casters may be necessary if the floor is not 
level.  NOTE:  Damage to equipment may result if not followed.  Unified 
Brands is not responsible for damage to equipment if improperly installed.

5.  Plug unit into power source.  Unit will come on.  If unit does not turn on, refer 

to controller operation section of this manual to manually turn on the unit.

6.  Allow unit time to cool down to holding temperature. If temperature 

adjustments are required, the control is located on the front panel.  Confirm 
that the units is holding the desired temperature.

7.  If unit has drawers, check drawer to ensure the drawer slides freely and fully 

extents along with seating in the cabinet properly when closed.

8.  Refer to the front of this manual for serial number location.  Please record 

this information in your manual on page 1 now.  It will be necessary when 
ordering replacement parts or requesting warranty service.

9.  Allow your unit to operate for approximately 45 minutes before putting in 

food in the rail.  Allow 2 hours for base of the unit to cool down to storage 
temperature, prior to loading product. NOTE:  All motors are oiled and sealed.

ELECTRICAL SUPPLY

The wiring should be done by a qualified electrician in accordance with local 
electrical codes.  A properly wired and grounded outlet will assure proper 
operation.  Please consult the data tag attached to the compressor to ascertain 
the correct electrical requirements.  Supply voltage and amperage requirements 
are located on the serial number tag. 

OPTIONAL BULLET-FEET ADJUSTMENT

The legs are equipped with bullet-type leveling bolts. Turn bolts clockwise or 
counterclockwise until the unit is level (both right to left and front to back). This 
can be done by hand or with an open end wrench. 

IMPORTANT - READ FIRST - IMPORTANT

INTERIOR EVAPORATOR COVER

EXTERIOR OF UNIT

RISK OF FIRE OR EXPLOSION. 

FLAMMABLE REFRIGERANT USED. 

DO NOT USE MECHANICAL DEVICES 

TO DEFROST REFRIGERATOR. DO NOT 

PUNCTURE REFRIGERANT TUBING.

RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. NO 

UTILICE DISPOSITIVOS MECÁNICOS PARA DESCONGELAR EL REFRIGERADOR. NO 

PERFORE LA TUBERÍA DEL REFRIGERANTE.

RISQUE D’INCENDIE OU 

D’EXPLOSION. 

INFLAMMABLE 

RÉFRIGÉRANT UTILISÉ. 

NE PAS UTILISER DE 

DISPOSITIFS 

MÉCANIQUES POUR 

DÉGIVRER LE 

RÉFRIGÉRATEUR. NE 

FAIRE AUCUN TUBE 

RÉFRIGÉRANT DE 

PONCTION.

DANGER

SB6.1.2

WARNING          ALERTE

CAUTION ATTENTIÓN

DO NOT REMOVE PANEL - HIGH VOLTAGE -

QUALIFIED PERSONNEL ONLY

NE PAS RETIRE LE PANNEAU - HAUTE TENSION -

PERSONNEL QUALIFIÉ SEULEMENT

NO RETIRE EL PANEL - ALTA TENSIÓN - 

CALIFICADO PERSONAL

MOVING PARTS, DO NOT OPERATE 

WITH COVER REMOVED

PIÉCES MOBILES NE PAS FAIRE 

FONCTIONNER SANS COUVERCLE

LAS PIEZAS DE MOVIMIENTO NO FUNCIONAN 

CON LA CUBIERTA RETIRADA

PP LBL1701 REV B

LABEL DIMENSION:  9 in x 3.25 in 

RISK OF FIRE OR EXPLOSION. 

DISPOSE OF PROPERLY IN 

ACCORDANCE WITH FEDERAL OR 

LOCAL REGULATIONS. 

FLAMMABLE REFRIGERANT USED.

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN. DESÉCHELO ADECUADAMENTE CONFORME 

A REGLAMENTOS FEDERALES O LOCALES. REFRIGERANTE INFLAMABLE UTILIZADO.

MISE EN GARDE

 RISQUE 

D’INCENDIE OU 

D’EXPLOSION. ÉLIMINER 

(or DISPOSER) 

CORRECTEMENT 

CONFORMÉMENT AUX 

RÉGLEMENTATIONS 

FÉDÉRALES OU LOCALES. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ.

SB6.1.4 

LABEL DIMENSION:  6 in x 2.75 in 

PP LBL1704 REV B

CAUTION

RISK OF FIRE OR EXPLOSION DUE TO 

PUNCTURE OF REFRIGERANT TUBING; FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY. 

FLAMMABLE REFRIGERANT USED.

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACIÓN DE LA TUBERÍA DE 

REFRIGERANTE; SIGA CUIDADOSAMENTE LAS INSTRUCCIONES DE MANEJO. REFRIGERANTE 

INFLAMABLE UTILIZADO.

MISE EN GARDE

 RISQUE 

D’INCENDIE OU 

D’EXPLOSION EN RAISON 

DE LA PERFORATION DU 

TUBE RÉFRIGÉRANT; 

SUIVEZ ATTENTIVEMENT 

LES INSTRUCTIONS DE 

MANIPULATION. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ.

CAUTION

SB6.1.5

PP LBL1705 REV B

LABEL DIMENSION:  6.25 in x 2.8 in 

RISK OF FIRE OR EXPLOSION. FLAMMABLE 

REFRIGERANT USED. CONSULT REPAIR MANUAL 

/ OWNER’S GUIDE BEFORE ATTEMPTING TO 

INSTALL OR SERVICE THIS PRODUCT. ALL 

SAFETY PRECAUTIONS MUST BE FOLLOWED. 

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE EL MANUAL DE REPARACIÓN / 

MANUAL DEL USUARIO ANTES DE INSTALAR O REPARAR ESTE PRODUCTO. DEBEN SEGUIRSE LAS PRECAUCIONES DE SEGURIDAD.

MISE EN GARDE 

RISQUE 

D’INCENDIE OU 

D’EXPLOSION. RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ. 

CONSULTER LE MANUEL DE 

RÉPARATION / GUIDE DE 

L’UTILISATEUR AVANT 

D’ESSAYER D’INSTALLER OU 

DE RÉPARER CE PRODUIT. 

TOUTES LES PRÉCAUTIONS 

DOIVENT ÊTRE RESPECTÉES.

SB6.1.3.b 

PP LBL1703 REVB

LABEL DIMENSION:  7.5 in x  5.36 in

SB6.1.3.a 

RISK OF FIRE OR EXPLOSION. FLAMMABLE 

REFRIGERANT USED. TO BE REPAIRED ONLY 

BY TRAINED SERVICE PERSONNEL. DO NOT 

PUNCTURE REFRIGERANT TUBING.

PELIGRO 

RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. DEBE SER REPARADO 

SOLAMENTE POR PERSONAL DE SERVICIO CAPACITADO. NO PERFORE LA TUBERÍA DEL REFRIGERANTE.

DANGER 

RISQUE 

D’INCENDIE OU 

D’EXPLOSION. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ. 

POUR ÊTRE RÉPARÉ QUE 

PAR UN TECHNICIEN 

QUALIFIÉ. NE PAS 

PERFORER LE TUBE 

RÉFRIGÉRANT.

CAUTION

DANGER

NEAR EXPOSED REFRIGERANT TUBING

NEAR MACHINE COMPARTMENT AND NAMEPLATE

Summary of Contents for PT-W-L Series

Page 1: ...AL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications without prior notice NOTICE Please read...

Page 2: ...pproximately 45 minutes before putting in food in the rail Allow 2 hours for base of the unit to cool down to storage temperature prior to loading product NOTE All motors are oiled and sealed ELECTRIC...

Page 3: ...curring POWER ON OFF Press and hold the Power Button for more than 3 seconds or until LED display turns On Off MANUAL DEFROST Press and hold the Defrost Button for more than 3 seconds melting snowflak...

Page 4: ...brands net Unified Brands believes strongly in the products it manufactures and backs those products with one of the best warranties in the industry We believe with the proper maintenance and use you...

Page 5: ...for this equipment before it is placed in service If you have any questions related to equipment set up operations or service please call 888 994 7636 In addition please review the sales terms and con...

Page 6: ...F CLOSING LEFT X X X X D3 IN GSK1020 GASKET PUSH IN LEFT RIGHT DOORS X X D3 IN GSK9902 GASKET PUSH IN LEFT RIGHT DOORS X D3 IN GSK1030 GASKET PUSH IN LEFT RIGHT DOORS X X X D4 RP DOR101 DOOR RIGHT 18...

Page 7: ...HP R290 EMBRACO START COMPONENTS X C3 RF CON1604 COMPRESSOR 1 4 HP R290 EMBRACO X X X C4 RF CON1604SC COMPRESSOR 1 4 HP R290 EMBRACO START COMPONENTS X X X C5 RF COI1603 CONDENSER COIL X X X X C6 RF F...

Page 8: ...X X X X B7 HD CST060 LOCKING CASTER STANDARD X X X X B8 HD CST061 NON LOCKING CASTER STANDARD X X X X B9 RP DCT2101 VERTICAL AIR DUCT REAR T07 2126 X X X X B10 RP DCT2102 VERTICAL AIR DUCT FRONT T07...

Page 9: ...R2102 EVAP HOUSING COVER T07 2116 X X X X E5 RP DRP2102 EVAP HOUSING DRAIN PAN T07 2121 X X X X E6 RP FRT2102 EVAP HOUSING FRONT T07 2120 X X X X E7 RP BCK2105 EVAP HOUSING REAR T07 2123 X X X X E8 RP...

Page 10: ...PAN SUPPORT 12 PAN OPENING FRONT BACK 25 8 T07 0087 X X T5 RP BAR1306 PAN SUPPORT 18 PAN OPENING BACK 38 75 T07 0088 X X X T5 RP BRK1504 PAN SUPPORT LEFT T07 0085 X X X X T5 RP BRK1505 PAN SUPPORT RI...

Page 11: ...ESS1902 BLK BLK EL WIR274 SR HARNESS1901 60 WHT EL WIR466F BLK BLK BRN WHT BLK WHT BLK RIBBED GRN GND BLK BRN WHT WHT BRN EL CNT1804 2 REQ D GRN GRN BLK WHT WHT BLK WHT 1 2 3 16FLA 96LRA 16 10 A 240V...

Page 12: ...GRN BLU GND BLK SR HARNESS1902 BLK BLK EL WIR274 SR HARNESS1901 60 WHT EL WIR466F BLK BLK BRN WHT BLK WHT BLK RIBBED GRN GND BLK BRN WHT WHT BRN EL CNT1804 2 REQ D GRN GRN BLK WHT WHT BLK WHT 1 2 3 1...

Page 13: ...13 OM PT W L SERIES PREP TABLES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...