background image

OM-PT-W-L SERIES PREP TABLES

you will feel tension as it grips the bill. Repeat this test all around the door. If the 
gasket does not seal tightly, replace the gasket after first checking the door for any 
sagging or warping.

SERVICE

CAUTION:  COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS. 

SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE 

PERSONNEL, SO AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO 

INCORRECT PARTS OR IMPROPER SERVICE.

CAUTION:  BEFORE MAKING ANY REPAIRS,  ENSURE THE UNIT IS DISCONNECTED  

FROM ITS POWER SOURCE.

This piece of equipment uses a R290 Refrigeration system.  This equipment has 
been clearly marked on the serial tag the type of refrigerant that is being used.   
There is also a warning labels stating that the unit contains R290 refrigerant. R290 
is safe to use as long as you follow these warning labels.  
No smoking or open flames when servicing this equipment.  If needed, use a CO2 
or powder type fire extinguisher.
Replacement parts used on any R290 Refrigeration system cabinet must have 
specific UL certification for non-sparking components. 
Only authorized service technician, certified in R290 system should service this 
equipment.

MANIFOLD SET

A R134A manifold set can be used for servicing this equipment.  

REFRIGERANT RECOVERY

Follow all national and local regulations for R-290 refrigerant recovery.  

LEAKING CHECKING AND REPAIR

Leak check an R-290 system the same way you would an R-134a or R-404A 
system with the following exceptions. 
1.  Do not use a Halid leak detector on a R290 system.
2.  Electronic leak detector must be designated specifically for combustible gas.
Use of a bubble solution or an ultrasonic leak detector are acceptable.   
When repairing a leak, it is recommended using oxygen free dry nitrogen with a 
trace gas not exceeding 200PSI. 
When accessing an R290 system, piercing valves are not to remain on the 
equipment in a permanent manner. After charge is recovered, Schrader valves 
are to be installed on the process stubs.  Proper charge is to be weighed into the 
system and the system is to be leak checked afterwards.
The R290 equipment must have red process tubes and other devices through 
which the refrigerant is serviced, such as any service port.  This color marking 
must remain on the equipment.  If marking is removed, it must be replace and 
extend at least 2.5 centimeters (1”) from the compressor.

CHARGING

Follow the charge amount specified on the data tag.  It is recommended to use the 
shortest hoses possible to prevent undercharging.
•  Ensure the system is sealed and leak checked 
•  Evacuate system to a minimum 500 micron
•  Weigh in correct charge
•  Leak check the system again
•  Bleed the refrigerant from the high side hose to the low side hose
•  Disconnect the hoses
•  Remove line taps

WARRANTY

Congratulations on the purchase of your new Unified Brands equipment. We hope you 
enjoy many years of reliable service in connection with the same. Please review all of 
the important safety and operational information contained in the Operator’s Manual 
for this equipment before it is placed in service. If you have any questions related to 
equipment set up, operations, or service, please call 888-994-7636.
In addition, please review the sales terms and conditions set forth below.

*****IMPORTANT NOTICE*****

WARRANTIES, LIMITATIONS ON WARRANTIES, AND LIMITATION OF REMEDIES

The following Warranties, Limitation on Warranties, and Limitation of Remedies are 
included in the terms of sale for this product. Please read this entire warranty and all 
warranty modifications, disclaimers, and limitations of remedies set forth herein before 
accepting or using this equipment or product. Customer acknowledges and accepts 
the provisions of this notice by Customer’s acceptance and use of the product. If these 
provisions are not acceptable and agreed to by Customer, then please return this 
product in its unused condition to Unified Brands or a Unified Brands authorized dealer.
UNIFIED BRANDS warrants this product against defects in material and workmanship 
under normal use and services for which this product was designed. This warranty 
runs only to the original end user and is in lieu of any other liability for defects. 
THE WARRANTIES EXPRESSED IN THESE TERMS AND CONDITIONS ARE IN PLACE 
OF ANY AND ALL OTHER EXPRESS WARRANTIES (UNLESS SEPARATELY STATED IN 
PRINTED MATERIAL PREPARED BY US DESCRIBING OUR EQUIPMENT) AND EXCLUDE 
ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE; NOR ARE THERE 
ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR 
OTHERWISE. In no event shall UNIFIED BRANDS be liable for damages or delay or 
for any consequential, special or contingent damages arising out of any breach of 
our warranty, whether or not we have knowledge of specific needs or our employees 
or agents have given any specific assurances. Anyone claiming that there has been 
a breach of warranty by UNIFIED BRANDS must give us written notice within THIRTY 
(30) days after discovery of the relevant defect or the right to assert such claim will 
have been waived conclusively and provided further that any such claim must also be 
asserted within the general warranty period for such equipment and/or parts.
UNIFIED BRANDS will not be liable for any expense incurred without our prior written 
authorization for alterations made outside of our factory or for repairs which are 
not performed by UNIFIED BRANDS authorized service departments using UNIFIED 
BRANDS factory parts. Nor shall we be responsible for the performance of equipment 
as to which any repairs, revisions or alterations have been made by others.
THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE EXCLUSIVE LIABILITY OF 
UNIFIED BRANDS OR ANY SELLER OF UNIFIED BRANDS PRODUCTS, FOR ANY AND ALL 
CLAIMS, LOSSES, INJURIES, OR DAMAGES (INCLUDING CLAIMS BASED ON BREACH 
OF WARRANTY, CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY, OR OTHERWISE) 
RESULTING FROM OR ARISING OUT OF THE USE OF HANDLING OF THIS PRODUCT, 
SHALL BE THE RETURN OF THE PURCHASE PRICE OR AN AMOUNT NOT TO EXCEED 
THE ORIGINAL PURCHASE PRICE OF THE PRODUCT OR, AT THE ELECTION OF UNIFIED 
BRANDS OR THE SELLER, THE REPLACEMENT OF THE PRODUCT.

https://unifiedbrands.net/
Randell-Warranty-Information

Summary of Contents for PT-W-L Series

Page 1: ...AL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications without prior notice NOTICE Please read...

Page 2: ...pproximately 45 minutes before putting in food in the rail Allow 2 hours for base of the unit to cool down to storage temperature prior to loading product NOTE All motors are oiled and sealed ELECTRIC...

Page 3: ...curring POWER ON OFF Press and hold the Power Button for more than 3 seconds or until LED display turns On Off MANUAL DEFROST Press and hold the Defrost Button for more than 3 seconds melting snowflak...

Page 4: ...brands net Unified Brands believes strongly in the products it manufactures and backs those products with one of the best warranties in the industry We believe with the proper maintenance and use you...

Page 5: ...for this equipment before it is placed in service If you have any questions related to equipment set up operations or service please call 888 994 7636 In addition please review the sales terms and con...

Page 6: ...F CLOSING LEFT X X X X D3 IN GSK1020 GASKET PUSH IN LEFT RIGHT DOORS X X D3 IN GSK9902 GASKET PUSH IN LEFT RIGHT DOORS X D3 IN GSK1030 GASKET PUSH IN LEFT RIGHT DOORS X X X D4 RP DOR101 DOOR RIGHT 18...

Page 7: ...HP R290 EMBRACO START COMPONENTS X C3 RF CON1604 COMPRESSOR 1 4 HP R290 EMBRACO X X X C4 RF CON1604SC COMPRESSOR 1 4 HP R290 EMBRACO START COMPONENTS X X X C5 RF COI1603 CONDENSER COIL X X X X C6 RF F...

Page 8: ...X X X X B7 HD CST060 LOCKING CASTER STANDARD X X X X B8 HD CST061 NON LOCKING CASTER STANDARD X X X X B9 RP DCT2101 VERTICAL AIR DUCT REAR T07 2126 X X X X B10 RP DCT2102 VERTICAL AIR DUCT FRONT T07...

Page 9: ...R2102 EVAP HOUSING COVER T07 2116 X X X X E5 RP DRP2102 EVAP HOUSING DRAIN PAN T07 2121 X X X X E6 RP FRT2102 EVAP HOUSING FRONT T07 2120 X X X X E7 RP BCK2105 EVAP HOUSING REAR T07 2123 X X X X E8 RP...

Page 10: ...PAN SUPPORT 12 PAN OPENING FRONT BACK 25 8 T07 0087 X X T5 RP BAR1306 PAN SUPPORT 18 PAN OPENING BACK 38 75 T07 0088 X X X T5 RP BRK1504 PAN SUPPORT LEFT T07 0085 X X X X T5 RP BRK1505 PAN SUPPORT RI...

Page 11: ...ESS1902 BLK BLK EL WIR274 SR HARNESS1901 60 WHT EL WIR466F BLK BLK BRN WHT BLK WHT BLK RIBBED GRN GND BLK BRN WHT WHT BRN EL CNT1804 2 REQ D GRN GRN BLK WHT WHT BLK WHT 1 2 3 16FLA 96LRA 16 10 A 240V...

Page 12: ...GRN BLU GND BLK SR HARNESS1902 BLK BLK EL WIR274 SR HARNESS1901 60 WHT EL WIR466F BLK BLK BRN WHT BLK WHT BLK RIBBED GRN GND BLK BRN WHT WHT BRN EL CNT1804 2 REQ D GRN GRN BLK WHT WHT BLK WHT 1 2 3 1...

Page 13: ...13 OM PT W L SERIES PREP TABLES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Reviews: