Troubleshooting
PROBLEM
POSSIBLE CAUSE
REMEDY
A. Refrigerator not running
1. Circuit breaker tripped.
2. Power cord unplugged
3. Thermostat turned off
4. Unknown
1. Reset
2. Plug in
3. Turn on
4. Call service agency
B. Condensing unit operates
for long periods or runs
continuously
1. Excessive heat load placed in unit
2. Prolonged or too frequent door
openings or door ajar
3. Gasket not sealing
4. Dirty condenser coil
5. Evaporator coil frozen
6. Unknown
1. Allow unit sufficient time to remove
heat.
2. Make sure door is closed when not in
use.
3. Adjust door or replace gasket.
4. Clean coil
5. Unplug unit, defrost coil then adjust
cold control to warmer position
6. Call service agency
C. Unit is noisy
1. Check for loose compressor
mounts
2. Check fan motor mounts
3. Check fan blades for obstructions
4. Check all panels, louvers and
covers
5. Unknown
1. Tighten if necessary
2. Tighten if necessary
3. Remove any obstructions. Tighten
or adjust shrouds.
4. Tighten and isolate as needed
5. Call service agency
D. Temperature too high
1. Check power cord and circuit
breaker
2. Temperature control set too high
3. Dirty condenser coil
4. Evaporator coil froze
5. Unknown
1. Plug in cord or reset breaker
2. Adjust control
3. Clean coil
4. Unplug unit, defrost coil then adjust
cold control to warmer position
5. Call service agency
E. Compressor runs but unit not
cooling
1. Fan blades have encountered an
obstruction
2. Unknown
1. Check for obstruction and free fan
blade
2. Call service agency
F. Product freezing
1. Check thermostat
2. Unknown
1. Replace or turn up
2. Call service agency
G. Door will not close
1. Check opening for obvious
obstruction
2. Check self closing spring
3. Check for loose or worn hinges
1. Remove any obstruction
2. Adjust or replace spring.
3. Replace hinges
H. Unit leaks water
1. Check for blockage in drain
2. Check for cracked drain pan
3. Check for level
4. Check for loose or disconnected
drain hose
1. Clean evaporator pan and clear drain
2. Inspect and replace if necessary
3. Level unit
4. Tighten or reconnect hose
14
Summary of Contents for 40000 Series
Page 16: ...o drafting service 4030g dgn Aug 20 1998 10 02 58...
Page 17: ...o drafting service 4030g dgn Aug 26 1998 14 42 23...
Page 18: ...MODEL 4030G PARTS DIAGRAM o drafting service 4030g dgn Aug 20 1998 09 26 59...
Page 21: ...o drafting service 40026 dgn Aug 28 1998 08 00 36...
Page 22: ...o drafting service 40026 dgn Aug 26 1998 14 37 34...