Randell 40000 Series Owner'S Manual Download Page 13

 

Recommended cleaners for your stainless steel include the 

following: 

 

JOB 

CLEANING AGENT 

COMMENTS 

Routine cleaning

 

Soap, ammonia, detergent Medallion

 

Apply with a cloth or sponge

 

Fingerprints & smears

 

Arcal 20, Lac-O-Nu, Ecoshine

 

Provides a barrier film

 

Stubborn stains and discoloration

 

Cameo, Talc, Zud, First Impression

 

Rub in the direction of the polish lines

 

Grease, fatty acids, blood and burnt on foods

 

Easy-off, Degrease It, Oven Aid

 

Excellent removal on all finishes

 

Grease and oil

 

Any good commercial detergent

 

Apply with a sponge or cloth

 

Restoration/Passivation

 

Benefit and Super Sheen

 

Good idea monthly

 

 

Reference: Nickel Development Institute, DiverseyLever, Savin, Ecolab, NAFEM 

Do not use steel pads, wire brushes, scrapers or chloride cleaners to clean your 

stainless steel. 

CAUTION: DO NOT USE ABRASIVE CLEANING SOLVENTS, NEVER USE HYDROCHLORIC ACID (MURIATIC ACID) 

ON STAINLESS STEEL.

 

Proper maintenance of equipment is the ultimate necessity in preventing costly repairs. By 

evaluating each unit on a regular schedule you can often catch and repair minor problems 

before they completely disable the unit and become burdensome on your entire operation. 

For more information on preventive maintenance consult your local service company or

 CFESA

 

member.

 Most repair companies offer this service at very reasonable rates to allow you the 

time you need to run your business along with the peace of mind that all your equipment will 

last throughout its expected life. These services often offer guarantees as well as the 

flexibility in scheduling of maintenance for your convenience. 

Randell believes strongly in the products it manufacturers and backs those products with one 

of the best warranties in the industry. We believe with the proper maintenance and use you 

will realize a profitable return on your investment and years of satisfied service. 

 

13

 

Summary of Contents for 40000 Series

Page 1: ...ignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a notation o...

Page 2: ...r superior products is the result of consistent quality craftsmanship From the earliest stages of product design to successive steps in fabrication and assembly rigid standards of excellence are maint...

Page 3: ...pecifications without prior notice Notice Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied Model Number ___...

Page 4: ...RANDELL MANUFACTURING SERIAL NUMBER LOCATIONS FOR THE 4030GA 40026SSA This is a sample of a serial number tag The serial number tag is located on the outside cabinet 4...

Page 5: ...40026SSA 4030GA 40026SSA Model L D H Style HP Volt AMP NEMA Ship Wt 4030GA 30 27 28 Counter top 1 3 115 60 1 7 5 15P 240 40026A 26 24 39 Pass thru 1 4 115 60 1 5 5 15P 240 40026SSA 26 24 39 Single se...

Page 6: ...ss or specialty methods of shipping is the responsibility of the customer Labor Coverage In the unlikely event a Randell manufactured unit fails due to defects in materials or workmanship within the f...

Page 7: ...ive compressor sent back freight prepaid 4 Furnish complete condensing unit or replacement package freight collect in exchange for the return of the defective compressor sent back freight prepaid deci...

Page 8: ...cretion of the Randell in house service technician Gasket Coverage Randell does not cover gaskets under warranty Gaskets are a maintenance type component that are subject to daily wear and tear and ar...

Page 9: ...ser The following conditions should be considered when selecting a location for your unit 1 Countertop load The countertop on which the merchandiser will display rest must be free of vibration and sui...

Page 10: ...ty D Door Inspection 1 Check doors to ensure that they are sealing properly 2 Check doors for proper alignment 3 Check doors to ensure that they open and shut freely E Installation Checklist After the...

Page 11: ...cabinet temperature remains to warm and your temperature control is at the maximum setting you may need to adjust the pressure control Your units pressure control should be set at the time of install...

Page 12: ...ts a preventive maintenance program which would include the following Monthly procedures 1 Cleaning of all condenser coils Condenser coils are a critical component in the life of the compressor and mu...

Page 13: ...VER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can...

Page 14: ...ions Tighten or adjust shrouds 4 Tighten and isolate as needed 5 Call service agency D Temperature too high 1 Check power cord and circuit breaker 2 Temperature control set too high 3 Dirty condenser...

Page 15: ...PONENTS RF CMP333 136 CONDENSOR 10 1 4 X 8 X 3 1 8 RFCOI115 137 CONDENSOR FAN MOTOR EL MTR085 138 CONDENSOR FAN BLADE 6 4 BLADE RF FAN011 140 FILTER DRYER 1 4 LINE RF FLT250A 141 CONDENSATE PAN W CLAM...

Page 16: ...o drafting service 4030g dgn Aug 20 1998 10 02 58...

Page 17: ...o drafting service 4030g dgn Aug 26 1998 14 42 23...

Page 18: ...MODEL 4030G PARTS DIAGRAM o drafting service 4030g dgn Aug 20 1998 09 26 59...

Page 19: ...DOOR FRAME HEATER 82 LONG EL WIR 256 78 FLOURESCENT LIGHT FIXTURE 20 RP LGT426F 79 BALLAST ELBLS100 92 ALUMINIZED PAINTED LID FOR UNIT 18 X 25 3 4 RP LID 426 94 LIGHT PANEL 11 1 2 X 26 COMPLETE W FIX...

Page 20: ...VAPORATOR FAN MOTOR EL MTR590 159 EVAPORATOR FAN BLADE RF FAN005 162 FAN MOUNTING BRACKET 12 3 4 RP BRK427 407 PLEXI GLASS LIGHT PANNEL 26 X 9 3 4 RP PNL426 407 GLASS SEE THRU 25 1 4 X 24 HD GLS144 51...

Page 21: ...o drafting service 40026 dgn Aug 28 1998 08 00 36...

Page 22: ...o drafting service 40026 dgn Aug 26 1998 14 37 34...

Page 23: ...o drafting service 40026 dgn Aug 26 1998 14 40 42 MODEL 40026 REFRIGERATOR CONDENSER PARTS DIAGRAM...

Page 24: ...UPPLY 2120 Solona St Ft Worth TX 76117 0009 1 800 433 1804 DEPOT 4 GENERAL PARTS 11311 Hampshire Ave South Bloomington MN 55438 1 800 279 9980 DEPOT 5 COMMERCIAL PARTS 5310 E 25th Street P O Box 18688...

Reviews: