C. Electrical
Supply
The wiring should be done by a qualified electrician in accordance with local electrical
codes. A properly wired, and grounded outlet will assure proper operation. Please consult
the data plate attached to the compressor to ascertain the correct electrical
requirements. Supply voltage and amperage requirements are located on the serial number
tag.
Note: It is important that a voltage reading be made at the compressor motor electrical
connections, while the unit is in operation, to verify that the correct voltage
required by the compressor is being supplied. Low or high voltage can detrimentally
affect operation and thereby void its warranty.
Note: It is important that your unit has its own dedicated line. Condensing units are
designed to operate with a voltage fluctuation of plus or minus 10% of the voltage
indicated on the unit data plate. Burn out of a condensing unit due to exceeding
voltage limits will void the warranty.
D. Door Inspection
1. Check doors to ensure that they are sealing properly.
2. Check doors for proper alignment.
3. Check doors to ensure that they open and shut freely.
E. Installation
Checklist
After the final location of the display merchandiser has been determined refer to the
following checklist prior to start up:
1. Check all exposed refrigeration lines to ensure that they are not kinked, dented or
rubbing together.
2. Check that condenser and evaporator fans rotate freely without striking any stationary
members.
3. Unit must be properly leveled.
4. Plug unit in and turn on main power switch and/or cold control.
5. Refer to the front of this manual for serial number location. Please record this
information in your manual on page 3 now. It will be necessary when ordering
replacement parts or requesting warranty service.
6. Confirm that unit is holding temperature. Set controls to desired temperature for your
particular ambient and altitude.
7. Allow your display merchandiser to operate for approximately 2
hours before putting in food. This allows interior to cool
down to the correct storage temperature.
Note: All motors are oiled and sealed.
10
Summary of Contents for 40000 Series
Page 16: ...o drafting service 4030g dgn Aug 20 1998 10 02 58...
Page 17: ...o drafting service 4030g dgn Aug 26 1998 14 42 23...
Page 18: ...MODEL 4030G PARTS DIAGRAM o drafting service 4030g dgn Aug 20 1998 09 26 59...
Page 21: ...o drafting service 40026 dgn Aug 28 1998 08 00 36...
Page 22: ...o drafting service 40026 dgn Aug 26 1998 14 37 34...