background image

difoodservice.com

7

not be held responsible for any carrier rate differences; rate differences are
entirely between the carrier and purchaser.

Point of shipping shall be

determined by Randell (Weidman, MI/Tucson, AZ).

At

dealer’s

request,

Randell will endeavor whenever practical to meet

dealer’s

request. Freight

charges to be collect unless otherwise noted.

DAMAGES

All crating conforms to general motor carrier specifications.

To avoid

concealed damage, we recommend inspection of every carton upon receipt.
In the event the item shows rough handling or visible damage to minimize
liability, a full inspection is necessary upon arrival. Appearance of damage will
require removing the crate in the presence of the driver.

A notation must be

placed on the freight bill and signed for by the truck driver at the time of
delivery.

Any and all freight damage that occurs to a Randell piece of

equipment as a result of carrier handling is not considered under warranty, and
is not covered under warranty guidelines. Any freight damage incurred during
shipping needs to have a freight claim filed by the receiver with the shipping
carrier.

Consignee is responsible for filing of freight claims when a clear

delivery receipt is signed.

Claims for damages must be filed immediately

(within 10 days) by the consignee with the freight carrier and all cartons and
merchandise must be retained for inspection.

RETURNED GOODS

Authorization for return must first be obtained from Randell before returning
any merchandise.

Any returned goods shipment lacking the return

authorization number will be refused, all additional freight costs to be borne by
the returning party. Returned equipment must be shipped in original carton,
freight prepaid and received in good conditions. Any returned merchandise is
subject to a minimum handling charge (consult factory for rate).

INSTALLATION

Equipment installation is the responsibility of the dealer and/or their customer.
Randell requires all equipment to be professionally installed.

PENALTY CLAUSES

Dealer penalty clauses, on their purchase order or contractually agreed to
between the dealer and their clients are not binding on Randell. Randell does
not accept orders subject to penalty clauses. This agreement supersedes any
such clauses in dealer purchase orders.

EXPORT POLICY

All quotations for export sales will be handled by Dorian Drake International
(

www.doriandrake.com

), Randell’s export management organization.

*FOOTNOTES IN REFERENCE TO PARAGRAPHS ABOVE
1.  Herein called Randell.
2.  NET means list price less discount, warranty, labor policy, freight, Randell delivery and other
miscellaneous charges.
CASH DISCOUNTS WILL BE CALCULATED ON NET ONLY.

Summary of Contents for 20042RF

Page 1: ...claim with the carrier We recommend that you do so at once Manufacture Service Questions 888 994 7636 P N OMANUAL_MNL0503 05 05 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 fax 888 864 7636...

Page 2: ...of Randell food service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality craftsmanship From the earli...

Page 3: ...andell Manufacturing reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended proc...

Page 4: ...window to allow for shipment installation and set up In the event equipment was shipped to a site other than the final installation site Randell will warranty for a period of three months following in...

Page 5: ...r sent back freight prepaid Decisions on whether or not to send complete condensing units will be made by Randell s in house service technician WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES Randell Man...

Page 6: ...ents for previously purchased equipment SANITATION REQUIREMENTS Certain areas require specific annotation requirements other than N S F U L standards Randell must be advised of these specifications be...

Page 7: ...amages must be filed immediately within 10 days by the consignee with the freight carrier and all cartons and merchandise must be retained for inspection RETURNED GOODS Authorization for return must f...

Page 8: ...675 20048SCF 48 32 5 26 2 27 ext 4 1 3 115 8 7 5 15P 400 20072SCF 72 32 5 26 4 27 ext 8 1 3 115 8 7 5 15P 530 20105SCF 105 32 5 26 6 27 ext 12 1 2 115 10 9 5 15P 675 Model L D H Drawers 12x20x4 Pan Ca...

Page 9: ...lines to ensure that they are not kinked dented or rubbing together 2 Check that the condenser and evaporator fans rotate freely without striking any stationary members 3 Unit must be properly levele...

Page 10: ...ge requirements are located on the serial number tag located inside the mechanical housing NOTE It is important that a voltage reading be made at the compressor motor electrical connections while the...

Page 11: ...difoodservice com 11 Electrical Diagrams...

Page 12: ...rigerated units A To lower the temperature 1 Turn the dial knob clockwise 2 There are numbers to indicate settings Keep the arrow on the knob pointed within the numbered section of the arc 3 Turning i...

Page 13: ...ase the down arrow 2 times until 14 is displayed Push and release the set button one time The new set point 14 will flash 3 times and then will be locked in NOTE It is recommended to only make changes...

Page 14: ...ean all gaskets on a weekly if not daily basis with a solution of warm water and a mild detergent to extend gasket life NOTE DO NOT USE SHARP UTENSILS RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INC...

Page 15: ...y disable the unit and become burdensome on your entire operation For more information on preventive maintenance consult your local service company or CFESA member Most repair companies offer this ser...

Page 16: ...16 800 621 8560 maintenance and use you will realize a profitable return on your investment and years of satisfied service...

Page 17: ...Defrost evaporator 2 Drawer not sealing properly 2 Check drawer seal 3 Drawer gasket damaged 3 Replace drawer gasket 4 Condenser coil dirty 4 Clean coil 5 Condenser fan faulty 5 Service condenser moto...

Page 18: ...ube clogged 1 Clean drain 2 Unit not level 2 Adjust leveling leg shim casters Unit noisy 1 Unit not level 1 Adjust leveling leg shim casters 2 Compressor mountings loose or hardened 2 Tighten or repla...

Page 19: ...difoodservice com 19 Replacement Parts 20000 Series Low Profile Equipment Stands...

Page 20: ...20 800 621 8560 ITEM DESCRIPTION PART 1 Drawer Front 27 Top RP FRT05T 1A Drawer Front 19 Top RP FRT118...

Page 21: ...justable bullet feet HD LEG9902 9 Mounting Plate for 27 Drawer RP MPT027 9A Mounting Plate for 19 Drawer RP MPT019 9B Mounting Plate for 32 Drawer RP MPT032 10 Thumb Screw HD PIN107 11 Drawer Track 2p...

Page 22: ...r 20105SCF EL MTR300 30 Condenser Fan Blade 20048SC 20072SC 20078SC 20105SC 20048SCF 20072SCF RF BLD0101 30A Condenser Fan Blade 20105SCF RF FAN007 31 Condensing Unit Shroud 20048SC RP SHD0505 31A Con...

Reviews: