difoodservice.com
13
A. Push and hold the
“set”
button until 12 appears and then release the
“set”
button. 12 is the current set point temperature.
NOTE: Standard
freezer units are preset to operate at 12° F.
B.
To lower the temperature
, push and release the up arrow 2 times until
10 is displayed. Push and release the
“set”
button one time. The new
set point, 10 will flash 3 times and then will be locked in.
C.
To raise the temperature
, push and release the down arrow 2 times
until 14 is displayed. Push and release the
“set”
button one time. The
new set point, 14, will flash 3 times and then will be locked in.
NOTE
:
It is recommended to only make changes of 2 degree increments
at a time. Allow for the unit to operate 24 hours between
adjustments. If the 2 degree adjustment is not enough another
adjustment can be made. The maximum highest setting is 25
degrees and the minimum lowest setting is 5 degrees. If the
settings need to go above or below this point there may be other
contributing factors as to the cause of the temperature variances,
please contact the factory at 1-800-621-8560.