background image

difoodservice.com

21

1B

Drawer Front, 32", Top

RP FRT35T

2

Drawer Front, 27”, Bottom

RP FRT05B

2A

Drawer Front, 19”, Bottom

RP FRT119

2B

Drawer Front, 32”, Bottom

RP FRT35B

3

Sculptured Handle, 12-13/16”

HD HDL130

4

Dial Thermometer

HD THR9901

5

Mechanical Housing Louver, 

20048SC

 & 

20072SC

 only

RP LVR0321

5A

Mechanical Housing Louver, 

20078SC

 only

RP LVR0505

5B

Mechanical Housing Louver, 

20105SC

 only

RP LVR0322

5C

Mechanical Housing Louver, 

20048SCF

 & 

20072SCF

 only

RP LVR0326

5D

Mechanical Housing Louver, 

20105SCF

 only

RP LVR0327

5E

Mechanical Housing Louver, 

20042R

 only

RP LVR0323

5F

Mechanical Housing Louver, 

20065R

 only

RP LVR0324

5G

Mechanical Housing Louver, 

20092R

 only

RP LVR0325

5H

Mechanical Housing Louver, 

20042RF

 only

RP LVR0506

5

I

Mechanical Housing Louver, 

20065RF

 only

RP LVR0507

5J

Mechanical Housing Louver, 

20092RF

 only

RP LVR0508

6

4 _” Heavy Duty Casters w/locking mechanism

HD CST030

6A

4 _” Heavy Duty Casters w/out locking mechanism

HD CST031

6B

5 _” Heavy Duty Casters w/locking mechanism

HD CST201

6C

5 _” Heavy Duty Casters w/out locking mechanism

HD CST200

7

Caster Shim Plate (20pc)

RP KIT0412

8

6” Stainless Steel Legs w/adjustable bullet feet

HD LEG9902

9

Mounting Plate for 27” Drawer

RP MPT027

9A

Mounting Plate for 19” Drawer

RP MPT019

9B

Mounting Plate for 32” Drawer

RP MPT032

10

Thumb Screw

HD PIN107

11

Drawer Track, 2pc. Set

RP TRK05SM

12

Roller Bearings for Drawer

HD BRG210

13

Drawer Frame, 27” Extendable

RP FRM127E

13A

Drawer Frame, 19” Non-extendable

RP FRM019

13B

Drawer Frame, 32” Extendable

RP FRM132E

14

Drawer Gasket, 27”

IN GSK1070

14A

Drawer Gasket, 19”

IN GSK1081

14B

Drawer Gasket, 32”

IN GSK1075

15

Fan Mounting Bracket for Coil Assembly

RP SHD107

16

Mounting Support Bracket for Coil Assembly

RP BRK006

17

Evaporator Fan Motor

EL MTR2338

18

Dial Temperature Control

HD CNT200

19

Plastic Bottom for Base Coil Assembly Box

RP DRP107

20

Heating Element for Coil Assembly, Freezer Units only

EL ELM9903

21

Refrigeration Valve for Coil Assembly

RF VLV200

22

Evaporator Coil

RP COI107

22A

Evaporator Coil Assembly, Refrigerated Units only

RF CSY0401

22B

Evaporator Coil Assembly, Freezer Units only

RP CSY0402

23

Shield Panel for Coil Assembly

RP PNL107

24

Power Cord, Male 9’

EL WIR461

25

Rocker On/Off Switch

EL SWT140

26

Power Cord, Female 12”

EL WIR469

27

Compressor, 20048SC

RF CMP010-134

27A

Compressor, 20072SC, 20078SC

RF CMP020-134

27B

Compressor, 20105SC

RF CMP0104P

27C

Compressor, 20048SCF, 20072SCF

RF CMP031P

27D

Compressor, 20105SCF

RF CMP9902P

Summary of Contents for 20042RF

Page 1: ...claim with the carrier We recommend that you do so at once Manufacture Service Questions 888 994 7636 P N OMANUAL_MNL0503 05 05 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 fax 888 864 7636...

Page 2: ...of Randell food service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality craftsmanship From the earli...

Page 3: ...andell Manufacturing reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended proc...

Page 4: ...window to allow for shipment installation and set up In the event equipment was shipped to a site other than the final installation site Randell will warranty for a period of three months following in...

Page 5: ...r sent back freight prepaid Decisions on whether or not to send complete condensing units will be made by Randell s in house service technician WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES Randell Man...

Page 6: ...ents for previously purchased equipment SANITATION REQUIREMENTS Certain areas require specific annotation requirements other than N S F U L standards Randell must be advised of these specifications be...

Page 7: ...amages must be filed immediately within 10 days by the consignee with the freight carrier and all cartons and merchandise must be retained for inspection RETURNED GOODS Authorization for return must f...

Page 8: ...675 20048SCF 48 32 5 26 2 27 ext 4 1 3 115 8 7 5 15P 400 20072SCF 72 32 5 26 4 27 ext 8 1 3 115 8 7 5 15P 530 20105SCF 105 32 5 26 6 27 ext 12 1 2 115 10 9 5 15P 675 Model L D H Drawers 12x20x4 Pan Ca...

Page 9: ...lines to ensure that they are not kinked dented or rubbing together 2 Check that the condenser and evaporator fans rotate freely without striking any stationary members 3 Unit must be properly levele...

Page 10: ...ge requirements are located on the serial number tag located inside the mechanical housing NOTE It is important that a voltage reading be made at the compressor motor electrical connections while the...

Page 11: ...difoodservice com 11 Electrical Diagrams...

Page 12: ...rigerated units A To lower the temperature 1 Turn the dial knob clockwise 2 There are numbers to indicate settings Keep the arrow on the knob pointed within the numbered section of the arc 3 Turning i...

Page 13: ...ase the down arrow 2 times until 14 is displayed Push and release the set button one time The new set point 14 will flash 3 times and then will be locked in NOTE It is recommended to only make changes...

Page 14: ...ean all gaskets on a weekly if not daily basis with a solution of warm water and a mild detergent to extend gasket life NOTE DO NOT USE SHARP UTENSILS RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INC...

Page 15: ...y disable the unit and become burdensome on your entire operation For more information on preventive maintenance consult your local service company or CFESA member Most repair companies offer this ser...

Page 16: ...16 800 621 8560 maintenance and use you will realize a profitable return on your investment and years of satisfied service...

Page 17: ...Defrost evaporator 2 Drawer not sealing properly 2 Check drawer seal 3 Drawer gasket damaged 3 Replace drawer gasket 4 Condenser coil dirty 4 Clean coil 5 Condenser fan faulty 5 Service condenser moto...

Page 18: ...ube clogged 1 Clean drain 2 Unit not level 2 Adjust leveling leg shim casters Unit noisy 1 Unit not level 1 Adjust leveling leg shim casters 2 Compressor mountings loose or hardened 2 Tighten or repla...

Page 19: ...difoodservice com 19 Replacement Parts 20000 Series Low Profile Equipment Stands...

Page 20: ...20 800 621 8560 ITEM DESCRIPTION PART 1 Drawer Front 27 Top RP FRT05T 1A Drawer Front 19 Top RP FRT118...

Page 21: ...justable bullet feet HD LEG9902 9 Mounting Plate for 27 Drawer RP MPT027 9A Mounting Plate for 19 Drawer RP MPT019 9B Mounting Plate for 32 Drawer RP MPT032 10 Thumb Screw HD PIN107 11 Drawer Track 2p...

Page 22: ...r 20105SCF EL MTR300 30 Condenser Fan Blade 20048SC 20072SC 20078SC 20105SC 20048SCF 20072SCF RF BLD0101 30A Condenser Fan Blade 20105SCF RF FAN007 31 Condensing Unit Shroud 20048SC RP SHD0505 31A Con...