background image

 

 

Heating 

(61

-86

(61

-86

(61

-86

(61

-86

8°C (46°F) Heating to avoid freezing water pipe in 

Kitchen 

Yes 

Yes 

Yes 

Yes 

°C & °F convertible   

Yes 

Yes 

Yes 

Yes 

2 Ways Draining Connection (Left or Right) 

Yes 

Yes 

Yes 

Yes 

Compressor Intelligent Pre-heating 

Yes 

Yes 

Yes 

Yes 

Smart Function 

Yes 

Yes 

Yes 

Yes 

Super Function 

Yes 

Yes 

Yes 

Yes 

Auto Restart 

Yes 

Yes 

Yes 

Yes 

Auto Defrost 

Yes 

Yes 

Yes 

Yes 

Auto Cleaning 

Yes 

Yes 

Yes 

Yes 

Quiet Mode 

Yes 

Yes 

Yes 

Yes 

24 Hours Timer 

Yes 

Yes 

Yes 

Yes 

Removable and washable Panel 

Yes 

Yes 

Yes 

Yes 

Louver Position Memory 

Yes 

Yes 

Yes 

Yes 

Washable High Definition Filter 

Yes 

Yes 

Yes 

Yes 

Horizontal Auto Swing Louver 

Yes 

Yes 

Yes 

Yes 

Chassis Electric heater function 

Yes 

Yes 

Yes 

Yes 

Healthy Filter(catechins,VC,HEPA,jasmine aroma 

filter) 

Optional 

Optional 

Optional 

Optional 

Wired control 

Optional 

Optional 

Optional 

Optional 

 

 

Model No. 

AS-09TR3SVDDH 

AS-12TR3SVEDH 

AS-18TR3SXADH 

AS-24TR3SBBDH 

Type 

T1, INVERTER 

T1, INVERTER 

T1, INVERTER 

T1, INVERTER 

Performance 

 

 

 

 

 

 

 

 

Cooling Capacity   

Btu/h 

9000   

12000   

18000   

24000   

        Heating Capacity   

Btu/h 

        Rated Input-Cooling 

820   

1079   

1700   

2290   

        Rated Input-Heating 

        SEER 

Cooling 

16.5   

16.9   

18.3   

17.2   

        HSPF 

Heating 

        EER for Cooling 

Btu/W 

10.98   

11.12   

10.59   

10.48   

        COP for Heating   

Btu/W 

 

 

        Moisture Removal   

L/H.r 

0.9   

1.2   

2.0   

2.4   

        Air Circulation   

m3/h 

550   

620   

1000   

1150   

        Refrigerant 

 

 

R410A 

R410A 

R410A 

R410A 

        Refrigerant charge volume 

640   

930   

1350   

1600   

        Indoor Sound 

Pressure(H/M/L/silence) 

dB (A) 

39/36/33/26 

40/36/33/26 

45/43/38/35 

48/45/40/36 

        Outdoor Sound pressure   

dB (A) 

53   

54   

56   

58   

        Voltage, Frequency, Phase 

230V~,208V~,60Hz,1P 

        Rated Current 

Cooling (A) 

3.7   

4.9   

7.6   

10.5   

Heating (A) 

System 

 

 

 

 

 

 

 

 

        Compressor type 

Rotary 

Rotary 

Rotary 

Rotary 

        Compressor MFG 

GMCC 

GMCC 

GMCC 

GMCC 

Summary of Contents for Celiera AS-09TR3SVDDH

Page 1: ...2018 Revision...

Page 2: ...DC AS 12UR3SXEDC AS 18TR3SBBDC AS 18UR3SBBDC AS 24TR3SDBDC AS 24UR3SDBDC AS 30UR3SDKVT AS 36UR3SDKVT Celiera Systems Inc MODELS AS 09TR3SVDDH AS 09UR3SVDDH AS 12TR3SVEDH AS 12UR3SVEDH AS 18TR3SXADH AS...

Page 3: ...5 2 1 Operation Instructions 31 5 2 2 Function Instructions 32 37 5 2 2A General Technical Parameters 32 5 2 2B Control Functions 32 37 6 Electrical Characteristics 38 6 1 Print Circuit Board Indoor...

Page 4: ...ll you need for most installation sites and maintenance conditions If you require help for a special problem contact our sales service outlet or your certified dealer for additional instructions In Ca...

Page 5: ...higher than drifting snow Provide snow vents When Connecting Refrigerant Tubing Use flare method for connecting tubing Apply refrigerant lubricant to matching surfaces of the flare and union tubes bef...

Page 6: ...208V 60Hz 1P Rated Current Cooling A 3 7 5 0 7 6 10 5 Heating A 3 9 5 0 9 0 10 4 System Compressor type Rotary Rotary Rotary Rotary Compressor MFG GMCC GMCC GMCC GMCC Compressor Model ASK89D53UEZ1 ASN...

Page 7: ...10 7 16 34 1 4x13 3 16x10 7 16 39 3 8x15 3 8x12 3 8 46 1 16x15 3 8x12 7 16 Outdoor Unit mm 830 530 340 830 530 340 940x640x385 995x730x445 Outdoor Unit in 32 11 16x20 7 8x13 3 8 32 11 16x20 7 8x13 3 8...

Page 8: ...r Optional Optional Optional Optional Wired control Optional Optional Optional Optional Model No AS 09TR3SVDDH AS 12TR3SVEDH AS 18TR3SXADH AS 24TR3SBBDH Type T1 INVERTER T1 INVERTER T1 INVERTER T1 INV...

Page 9: ...roove tube f Condensor length x height x width mm 695x462x36 4 695 400 x462x36 4 842 813 x546x36 4 842x378x27 2 Tube pitch a x row pitch b mm 21x18 19 21x18 19 21x18 19 21x13 6 Fin spacing mm 1 4 1 4...

Page 10: ...ng to avoid freezing water pipe in Kitchen No No No No C F convertible Yes Yes Yes Yes 2 Ways Draining Connection Left or Right Yes Yes Yes Yes Compressor Intelligent Pre heating No No No No Smart Fun...

Page 11: ...ant charge volume g 950 1160 1550 1880 Indoor Sound Pressure H M L silence dB A 38 32 29 26 39 32 29 26 45 41 37 34 48 45 40 36 Outdoor Sound pressure dB A 53 53 55 58 Voltage Frequency Phase V 230V 2...

Page 12: ...16x9 5 8 Outdoor Unit mm 715 482 240 810x585x280 860x650x310 885 795 366 Outdoor Unit in 28 1 8x19x9 7 16 31 7 8x23x11 33 7 8x25 9 16x12 3 16 34 7 8x31 5 16x14 3 8 Net Weight Kg Indoor Unit 8 5 9 0 1...

Page 13: ...Yes Yes 24 Hours Timer Yes Yes Yes Yes Removable and washable Panel Yes Yes Yes Yes Louver Position Memory Yes Yes Yes Yes Washable High Definition Filter Yes Yes Yes Yes Horizontal Auto Swing Louver...

Page 14: ...pressor type Rotary Rotary Rotary Rotary Compressor MFG Hitachi GMCC GMCC GMCC Compressor model ASD088RKQA6JT6 ASN108D32UFZ ATM150D43UFZ ATF235D22UMT Expansion Device capillary capillary capillary cap...

Page 15: ...3 16 34 7 8x31 5 16x14 3 8 Net Weight Kg Indoor Unit 8 5 9 0 14 5 14 5 Outdoor Unit 26 0 33 0 44 54 Packing Dimensions WxHxD mm With pipe Indoor Unit mm 900 335 260 900 335 260 1210 390 315 1210 390 3...

Page 16: ...Yes Yes Yes Washable High Definition Filter Yes Yes Yes Yes Horizontal Auto Swing Louver Yes Yes Yes Yes Chassis Electric heater function No No No No Vertical Auto Swing Louver Yes Yes Yes Yes Healthy...

Page 17: ...rows 2 2 5 Tube outside dia and type mm 7 innergroove tube 7 innergroove tube f Condensor length x height x width mm 970 942 x756x18 19 970 942 550 x756x18 19 Tube pitch a x row pitch b mm 21x18 19 2...

Page 18: ...16 30 61 86 Remote Control Adjustable Temperature Range Heating 16 30 61 86 16 30 61 86 8 C 46 F Heating to avoid freezing water pipe in Kitchen Yes Yes C F convertible Yes Yes 2 Ways Draining Connect...

Page 19: ...19 3 Product Pictures and Dimensions 3 1 1 Product Pictures Indoor Units Unit View DF Panel VQ Panel...

Page 20: ...20 3 1 2 Product Pictures Outdoor Units Unit V W1M X W1P Unit B W2N D W5F 3 1 3 Product Pictures Remote controller Unit View J1...

Page 21: ...R3SXADH 915 315 236 AS 18UR3SXADH 915 315 236 AS 24TR3SBBDH 1085 315 236 AS 24UR3SBBDH 1085 315 236 AS 09TR3SVEDC 870 270 214 AS 09UR3SVEDC 870 270 214 AS 12TR3SXEDC 870 270 214 AS 12UR3SXEDC 870 270...

Page 22: ...73 810 280 585 338 AS 24TR3SBBDH 542 341 935 860 310 667 368 AS 24UR3SBBDH 542 341 935 860 310 667 368 AS 09TR3SVEDC 443 264 776 715 240 486 290 AS 09UR3SVEDC 443 264 776 715 240 486 290 AS 12TR3SXEDC...

Page 23: ...will support the weight of the unit Select a location where copper tubing and condensation drain hose have the shortest run to outdoors See A Allow room for operation and maintenance as well as unrest...

Page 24: ...a minimum of 10 cm above ground level to reduce humidity and protect the unit against possible water damage and decreased service life Install rubber cushions under unit feet to reduce vibration and...

Page 25: ...ADH 1854605 1854707 AS 24TR3SBBDH 1854605 1854707 AS 24UR3SBBDH 1854698 1854707 AS 09TR3SVEDC 1854698 1854707 AS 09UR3SVEDC 1854605 1854707 AS 12TR3SXEDC 1854605 1854707 AS 12UR3SXEDC 1854605 1854707...

Page 26: ...26 1854605 1854698...

Page 27: ...27 4 2 3 Outdoor Diagrams 1854707...

Page 28: ...28 4 3 Refrigerant Flow System NOTE In different models throttle assembly may be Capillary OR Electronic expansion valve...

Page 29: ...r at least 15mins and make sure reading on multi meter is 1 0 X105 pa 76cmHg 6 Check the vacuum with the gage manifold valve then close the gage manifold valve and stop the vacuum pump 7 Let it set fo...

Page 30: ...electrical malfunction Is the power cord correct and sufficient Poor cabling may cause electric malfunction or damage to system Are any inlet and outlet openings blocked Blockage may cause insufficie...

Page 31: ...on Range Cooling and Heating SEER 17 Temperature Indoor Air Intake Temp Outdoor Air Intake Temp COOLING Maximum 30 46 Minimum 16 16 HEATING Maximum 30 24 Minimum 20 5 2 Remote Controller Operation Fun...

Page 32: ...n power is restored and the unit is turned back on Settings saved include Operation Mode Air Volume Temperature Setting and Forced Cooling The only setting lost is Air Flow Direction To turn on the sy...

Page 33: ...r 5 min elapse Those indicators will be recovery when the temperature or Time setting is adjusted after the setting the indicators will be lit in 10 sec then turn OFF Automatic run SMART mode When the...

Page 34: ...ng When the difference between setting temperature and room temperature equal 2 C or 4 C indoor fan speed will remain steady Air flow direction control The louver is derived by a step motor and it swi...

Page 35: ...louver recovers to the original position after the air volume change to LOW When the room temperature reach to the setting temperature the compressor will be turn off and the air flow change to LOW t...

Page 36: ...s activated immediately In the change from cooling to heating it needs an interval of 50 seconds for the 4 way valve to change over from being interrupted to being activated SUPER function mode option...

Page 37: ...ing prohibition of frequency rising is released Conditions for defrosting A When the heating compressor consecutively runs for 40 minutes EEPROM setting value at the current operating mode B If the am...

Page 38: ...3SBBDH AS 18TR3SBBDC AS 18UR3SBBDC AS 24TR3SDBDC AS 24UR3SDBDC 1 Interface of PG motor 2 Room temperature sensor 3 Pipe temperature sensor 4 Switch button 5 Feedback from PG motor 6 Up down swing 7 Le...

Page 39: ...36UR3SDKVT Models of Outdoor Unit AS 09TR3SVDDH AS 09UR3SVDDH AS 12TR3SVEDH AS 12UR3SVEDH AS 09TR3SVEDC AS 09UR3SVEDC 1 Interface of PG motor 2 Room and Pipe temperature sensor 4 Switch button 6 swin...

Page 40: ...ssor discharge temperature sensor 2 Terminal of reactor 6 Terminal of live wire connect to the terminal panel 2 L 10 Terminal of electronic expansion valve 14 Terminal of compressor overload protector...

Page 41: ...al of compressor 7 Outdoor ambient temperature sensor 12 Terminal of AC fan 17 Terminal of live wire 3 Terminal of DC fan 8 Outdoor pipe temperature sensor 13 Cool Valve terminal 18 Terminal of neutra...

Page 42: ...e after such shock But it may be found later this type of mishandling void our warranty Test resistance TOOL Multimeter Test the resistance of the main winding The indoor fan motor is fault if the res...

Page 43: ...43 6 2 2 Indoor DC Fan Motor Outdoor DC Fan Motor 6 2 3 Outdoor DC Fan Motor...

Page 44: ...342947037 4 17 954 1 10609872 47 2 444 3 380169671 3 17 158 1 14565549 48 2 363 3 416856492 2 16 401 1 18599135 49 2 286 3 45247766 1 15 683 1 22696435 50 2 211 3 487894953 0 15 1 26865672 51 2 139 3...

Page 45: ...15 241 1 542579738 12 348 264 0 09575738 59 14 684 1 582573078 11 330 048 0 10093573 60 14 151 1 622834232 10 312 904 0 10634837 61 13 64 1 663405088 9 296 761 0 11200385 62 13 151 1 704175229 8 281 5...

Page 46: ...703 3 237170332 31 44 537 0 66229036 102 3 602 3 268602192 32 42 676 0 68720188 103 3 501 3 300650422 33 40 904 0 71272849 104 3 409 3 33039475 34 39 217 0 73885738 105 3 317 3 360680043 35 37 609 0 7...

Page 47: ...ing the plugs Don t leave the compressor in open air for a long time Avoiding compressor running in reverse caused by connecting electrical wire incorrectly Warning In case AC voltage is impressed to...

Page 48: ...mperature sensor is failure c the outdoor control board is failure Communication failure between the indoor unit and outdoor unit a the communication cable connect loose b the communication cable is f...

Page 49: ...protection with cooling or overload protection with heating in indoor unit a the indoor coil temperature sensor connect loose b the indoor coil temperature sensor is failure c the indoor control boar...

Page 50: ...he lights flash every two seconds for the following faults Protection against overheated outdoor radiator a Radiator sensors fail b Detection circuit of the sensor on the control panel fails Protectio...

Page 51: ...communication between display board and control board have in trouble a The connection between the display board and control board is loose b The indoor control board is failure c The wiring of the di...

Page 52: ...normal 7 Communication failure between the indoor unit and outdoor unit a communication cable connection loose b communication cable failure c connection between filter board and outdoor control board...

Page 53: ...indoor coil temperature sensor connection loose b indoor coil temperature sensor failure c indoor control board failure d refrigerant system abnormal 17 PFC protection a PFC failure b outdoor drive bo...

Page 54: ...mmunication cable loose b communication cable failure c connection between filter board and outdoor control board incorrect or loose d connection between filter board and terminal incorrect or loose e...

Page 55: ...protective under voltage value for five seconds over voltage under voltage protection starts Protection actions against AC input over voltage under voltage The system stops operation Conditions for e...

Page 56: ...to anti overload prohibition of frequency of outdoor coiled pipe The frequency of compressor maintains at the current level which may decrease as the case requires while cannot rise The indoor and ou...

Reviews: