![Ramsond Celiera AS-09TR3SVDDH Service Manual Download Page 11](http://html1.mh-extra.com/html/ramsond/celiera-as-09tr3svddh/celiera-as-09tr3svddh_service-manual_3605888011.webp)
11
Rated Input-Cooling
W
670
920
1385
2035
Rated Input-Heating
W
730
1130
1595
2080
SEER
Cooling
21.5
20.5
23.3
20.5
HSPF
Heating
10.5
10.8
11.6
11.8
EER for Cooling
Btu/W
13.43
13.04
13.00
11.73
COP for Heating
Btu/W
13.01
11.50
11.90
11.78
E-STAR__V5.0
ASHP: SEER>15, EER>12.5,
HSPF>8.5
CAC: SEER>15, EER>12.5
Yes
Yes
Yes
No
Most Efficient 2016
ASHP: SEER>20, EER>12.5,
HSPF>10
CAC: SEER>20, EER>12.5
Yes
Yes
Yes
No
CEE Qualifying Tier
Tier0 - 14.5SEER, 12EER,
(8.5HSPF)
Tier1 - 15SEER, 12.5EER,
(8.5HSPF)
Tier2 - 16SEER, 13EER,
(9HSPF)
Tier3 - 18SEER,13EER,
(10HSPF)
Tier3
Tier3
Tier3
No
Moisture Removal
L/H.r
0.9
1.2
1.5
2.4
Air Circulation
m3/h
580
620
1100
1200
Refrigerant
R410A
R410A
R410A
R410A
Refrigerant charge
volume
g
950
1160
1550
1880
Indoor Sound
Pressure(H/M/L/silence)
dB (A)
38/32/29/26
39/32/29/26
45/41/37/34
48/45/40/36
Outdoor Sound
pressure
dB (A)
53
53
55
58
Voltage, Frequency,
Phase
V
230V~,208V~,60Hz,1P
Rated Current
Cooling (A)
3.1
4.1
6.3
9.2
Heating (A)
3.3
5.0
7.2
9.3
System
Compressor type
Rotary
Rotary
Rotary
Rotary
Compressor MFG
Hitachi
GMCC
GMCC
GMCC
Compressor model #
ASD088RKQA6JT6
ASN108D32UFZ
ATM150D43UFZ
ATF235D22UMT
Expansion Device
capillary
capillary
capillary
capillary
Indoor DC motor
No
No
Yes
Yes
Indoor motor power output
W
14
14
35
35
Indoor motor speed
S/H/M/L
1250/1100/9500
1250/1100/9500
1100/960/800
1200/1040/880
Outdoor DC motor
Yes
Yes
Yes
Yes
Outdoor motor power input
W
30
30
60
61
Outdoor motor speed
H/M/L
880/650/450
800/650/450
840/650/500
1200/550/500
Evaporator
Evaporator material
Copper tube and Aluminum Fin
Number of rows
2
2
2
2