11
RAM 100 • 1000 • 5500
RAMSET
www.ramsetinc.com
MASTER / SLAVE INSTALLATION
(RH) Right Hand operation requires Dip Switch
(C7) "Left/Right" to be ON.
Dip Switch “C”
Three pushbuttons are located under the dip switches for operation of the gate (see Figure 15). The
opening,
stop
and
closing
buttons can be utilized to set limit switches and verify proper system operation when
installing or servicing an operator.
Opening
Pressing this button will cause the gate to open.
Stop
Pressing this button will cause the gate to
stop moving.
Closing
Pressing this button will cause the gate to close.
Reset E.R.D. Board
Push all three pushbuttons for approximately
5 seconds. All three L.E.D.’s should blink.
L.E.D.’s light up when Opening,
Closing or Stopped
“Intelligate” Control Board
PUShBUTTON CONTROLS
Figure 16
Figure 15