Disconnect power before disassembly or cleaning. Never immerse or directly spray cable and connectors 

with liquids. Clean cables with commercially available biodegradable cleaning solutions. Do not use 
solvents containing hydrocarbons (i.e. MEK, Acetone). 

There are no user serviceable parts. Contact factory for replacement part applicability. 

Do not change make or model number the power extension cables for any reason! 

Cautions 

 

The ATEX / IECEx Power Extension Cables are intended for use in Explosive Atmospheres in accordance 

with ATEX Directive 2014/34/EU. It is the user's responsibility to determine the suitability of the power 
extension cables for the intended purpose. 

CAUTION! THESE POWER EXTENSION CABLES ARE NOT INTENDED FOR USE IN MINES SUSCEPTIBLE TO 

FIREDAMP.

 

Do not operate if there is any physical damage to cord, plug or receptacle. 

Fatal electrical shock may result if power extension cables are not grounded in compliance with electrical 

code. 

Keep away from children. 

ATEX / IECEx Extension Cable Rating: 

II 2 G Ex db eb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db 

Euramco Safety hereby declares that the equipment listed in this manual conforms to the relevant 

Essential Health and Safety Requirements of the European Machinery Directive and standards listed 
below. 

Standards to which conformity is declared: See Declaration of Conformity (last page). 

The ATEX / IECEx 

Power Extension Cables complies with International Standards EN 60079-0:2012+A11:2013, EN 60079-
1:2014, EN 60079-7:2015, & EN60079-31:2014. 

Category, Group and Zone Classifications

 

According to ATEX Directive (2014/34/EU) 
The power cables are built with three critical parts; Cable, Plug, and Couplers.  The H07RN-F cables were 

selected based on the need for extra heavy-duty applications.  Plugs and couplers were selected based 
on the most used European connectors for hazardous locations. 
    

The Power Extension Cables have been certified to meet the ATEX Directive 2014/34/EU certification for 

II 2 G Ex db eb IIC T6 Gb, II 2 D Ex tb IIIC T80°C Db 

Accessories 

 

None 

SM-ECXCABLE Rev B 

Summary of Contents for ECX-110

Page 1: ...Instruction Manual ATEX IECEX ECX 110 ECX 240 POWER EXTENSION CABLE SM ECXCABLE Rev B ...

Page 2: ...ologies available Every product is constructed to demanding and exact specifications for quality performance and reliability When human life depends on having a fan that can deliver clean safe air you have only one choice you can trust RAMFAN Explore our website and online catalog at www euramco com and discover how RAMFAN can make a difference in the field All product information in the publicati...

Page 3: ...n 4 6 Model Numbers 7 Maximum Cable Length 8 Installation Instructions Care 9 11 Cautions 11 Warranty 12 How to Maintain Cables 12 Declaration of Conformity 13 Original Manufacturer s Installation Instructions 14 SM ECXCABLE Rev B ...

Page 4: ...uplers were selected based on the most used European connectors for hazardous locations The ATEX IECEx ECX 110 ECX 240 power extension cables are sold to our distributors end users as fully assembled compliant power extension cables No post assembly is required The drawing below depicts the ATEX IECEx Power cable application used to extend the reach of a portable ATEX fan with H07RN F cable and wi...

Page 5: ...5 ...

Page 6: ...cation II 2 G Ex db eb IIC T6 Gb II 2 D Ex tb IIIC T80 C Db Zone 1 2 21 22 0539 Demko 20 ATEX 2364X IECEx UL 20 0034X Special Conditions for Safe Use The letter X at the end of the ATEX IECEx certificate numbers indicates a special condition for safe use this special condition of safe use for the ATEX IECEx power extension cables states that the coupling socket devices must not be used in dust are...

Page 7: ...7 Model ECX 110 ATEX IECEx Power Ext Cable for 110 130VAC 15 meter or 30 meter Model ECX 240 ATEX IECEx Power Ext Cable for 200 250VAC 15 meter or 30 meter Model Numbers SM ECXCABLE Rev B ...

Page 8: ...8 SM ECXCABLE Rev B ...

Page 9: ...l prevent them being exposed to mechanical damage to corrosion or chemical influences for example solvents to the effects of heat and to the effects of UV radiation These are the minimum allowed bend radii for the cables 1 5mm 4in 2 5mm 5 5in 4 0mm 6 2in The bend radius of the cable should start at least 25mm from the end of the cable Note For ATX connectors lift dust covers and insert plug into c...

Page 10: ...LTAGE PLUG WALL SOCKETS COUPLER 100 130V GHG 511 7304 R0001 GHG 511 4304 R0001 GHG 511 3304 R0001 GHG 511 4304 R0002 GHG 511 4304 R3001 GHG 511 4304 R3003 GHG 511 8304 R0001 200 250V GHG 511 7306 R0001 GHG 511 4409 R0001 GHG 511 3306 R0001 GHG 511 4409 R3001 GHG 511 4409 R3003 GHG 511 8409 R0001 R STAHL Connector Installation and Removal R Stahl Plug to Socket Coupler Compatible Table VOLTAGE PLUG...

Page 11: ...ded in compliance with electrical code Keep away from children ATEX IECEx Extension Cable Rating II 2 G Ex db eb IIC T6 Gb II 2 D Ex tb IIIC T80 C Db Euramco Safety hereby declares that the equipment listed in this manual conforms to the relevant Essential Health and Safety Requirements of the European Machinery Directive and standards listed below Standards to which conformity is declared See Dec...

Page 12: ... during maintenance work on their device Firm fit of the conductors Damage on the enclosure seals or surface Dirt on the sleeves Compliance with the permissible temperatures according to IEC EN 60079 Whether the device is used in accordance with its intended use Cleaning To avoid electrostatic charging the devices located in potentially explosive areas may only be cleaned using a damp cloth When c...

Page 13: ...13 Declaration of Conformity SM ECXCABLE Rev B ...

Page 14: ...14 ORIGINAL MANUFACTURER S INSTALLATION INSTRUCTIONS SM ECXCABLE Rev B ...

Page 15: ...SM ECXCABLE Rev B EURAMCO GROUP ...

Reviews: