SM-ECXCABLE Rev B 

Installation Instruction and Care 

 

The ECX-110 & ECX-240 power extension cables are fully assembled and ready for use upon receipt.  No post assembly 

required. 

1.

 

Completely uncoil power extension cable as to be used between AC power source and electrical device. 

2.

 

Inspect cable and connectors for damage or wear that could render the cable unsafe for hazardous locations.   

3.

 

Route cable to avoid contact with heavy machinery that could possibly damage cable or possible be a trip hazard 
for workers. Cables must be integrated into a system in a way to support accessibility for regular maintenance. 

4.

 

Connect plug end of the power extension cable to the AC power source. 

5.

 

Verify AC power source is providing an electrical ground connection.   

6.

 

Verify electrical device is turned OFF before attaching power extension cable.

 

7.

 

Connect coupler end of cable to the electrical device.   

The power extensions shall be installed, so far as is practicable, in positions that will prevent them being exposed to 
mechanical damage, to corrosion or chemical influences (for example solvents), to the effects of heat and to the effects 
of UV radiation. 

These are the minimum allowed bend radii for the cables.   1.5mm²: 

4in, 2.5mm² 

5.5in, 4.0mm² 

6.2in.   

The bend radius of the cable should start at least 25mm from the end of the cable. 

Note:

  For ATX connectors lift dust covers and insert plug into coupler until coupler dust cap latches snaps into position 

on plug.  To break connection between coupler and plug lift dust cap to pull connectors apart. 

Note:

  For CEAG connectors lift dust cover, insert plug into coupler, and rotate clockwise, to lock plug into coupler and 

to close power switch within the coupler.  To break connection between coupler and plug lift dust cap and rotate plug 
counterclockwise to pull connectors apart. 

Note:

  For R. STAHL connectors insert plug into coupler and rotate outer ring clockwise to secure plug to coupler. 

A.T.X. Connector Installation and Removal

 

 

A.T.X:   Plug to Socket & Coupler Compatible Table

 

VOLTAGE      

PLUG  

  

  

WALL SOCKETS  

  

COUPLER

 

100 / 130V  

PRE316PY  

  

  PRE316RY  

  

PRE316MY 

  

  

  

  

  

  PRE316FY  

200 / 250V  

PRE316PB  

  

  PRE316RB  

  

PRE316MB 

  

  

  

  

  

  PRE316FB 

Plug 
removal

 

 

Plug 
insertion

 

 

Summary of Contents for ECX-110

Page 1: ...Instruction Manual ATEX IECEX ECX 110 ECX 240 POWER EXTENSION CABLE SM ECXCABLE Rev B ...

Page 2: ...ologies available Every product is constructed to demanding and exact specifications for quality performance and reliability When human life depends on having a fan that can deliver clean safe air you have only one choice you can trust RAMFAN Explore our website and online catalog at www euramco com and discover how RAMFAN can make a difference in the field All product information in the publicati...

Page 3: ...n 4 6 Model Numbers 7 Maximum Cable Length 8 Installation Instructions Care 9 11 Cautions 11 Warranty 12 How to Maintain Cables 12 Declaration of Conformity 13 Original Manufacturer s Installation Instructions 14 SM ECXCABLE Rev B ...

Page 4: ...uplers were selected based on the most used European connectors for hazardous locations The ATEX IECEx ECX 110 ECX 240 power extension cables are sold to our distributors end users as fully assembled compliant power extension cables No post assembly is required The drawing below depicts the ATEX IECEx Power cable application used to extend the reach of a portable ATEX fan with H07RN F cable and wi...

Page 5: ...5 ...

Page 6: ...cation II 2 G Ex db eb IIC T6 Gb II 2 D Ex tb IIIC T80 C Db Zone 1 2 21 22 0539 Demko 20 ATEX 2364X IECEx UL 20 0034X Special Conditions for Safe Use The letter X at the end of the ATEX IECEx certificate numbers indicates a special condition for safe use this special condition of safe use for the ATEX IECEx power extension cables states that the coupling socket devices must not be used in dust are...

Page 7: ...7 Model ECX 110 ATEX IECEx Power Ext Cable for 110 130VAC 15 meter or 30 meter Model ECX 240 ATEX IECEx Power Ext Cable for 200 250VAC 15 meter or 30 meter Model Numbers SM ECXCABLE Rev B ...

Page 8: ...8 SM ECXCABLE Rev B ...

Page 9: ...l prevent them being exposed to mechanical damage to corrosion or chemical influences for example solvents to the effects of heat and to the effects of UV radiation These are the minimum allowed bend radii for the cables 1 5mm 4in 2 5mm 5 5in 4 0mm 6 2in The bend radius of the cable should start at least 25mm from the end of the cable Note For ATX connectors lift dust covers and insert plug into c...

Page 10: ...LTAGE PLUG WALL SOCKETS COUPLER 100 130V GHG 511 7304 R0001 GHG 511 4304 R0001 GHG 511 3304 R0001 GHG 511 4304 R0002 GHG 511 4304 R3001 GHG 511 4304 R3003 GHG 511 8304 R0001 200 250V GHG 511 7306 R0001 GHG 511 4409 R0001 GHG 511 3306 R0001 GHG 511 4409 R3001 GHG 511 4409 R3003 GHG 511 8409 R0001 R STAHL Connector Installation and Removal R Stahl Plug to Socket Coupler Compatible Table VOLTAGE PLUG...

Page 11: ...ded in compliance with electrical code Keep away from children ATEX IECEx Extension Cable Rating II 2 G Ex db eb IIC T6 Gb II 2 D Ex tb IIIC T80 C Db Euramco Safety hereby declares that the equipment listed in this manual conforms to the relevant Essential Health and Safety Requirements of the European Machinery Directive and standards listed below Standards to which conformity is declared See Dec...

Page 12: ... during maintenance work on their device Firm fit of the conductors Damage on the enclosure seals or surface Dirt on the sleeves Compliance with the permissible temperatures according to IEC EN 60079 Whether the device is used in accordance with its intended use Cleaning To avoid electrostatic charging the devices located in potentially explosive areas may only be cleaned using a damp cloth When c...

Page 13: ...13 Declaration of Conformity SM ECXCABLE Rev B ...

Page 14: ...14 ORIGINAL MANUFACTURER S INSTALLATION INSTRUCTIONS SM ECXCABLE Rev B ...

Page 15: ...SM ECXCABLE Rev B EURAMCO GROUP ...

Reviews: