background image

The Ramblegard Central Monitor Display is an        

affordable falls management and nurse-call 

solution for Care Homes & Hospital wards. 

Caregivers can conveniently read a large LED 

display from a distance, and the panel can also 

forward signals to a Caregiver Alert Pager that 

will display call type and device ID. 

Alarms can be reset using a wireless reset 

button, cordless monitor, pager, or at the panel. 

Straightforward programming allows users to 

quickly  set  up  the  system,  and  easily  add/remove            

devices based on changes in daily requirements.

Summary of Contents for RG43

Page 1: ...Display Monitor RG43 User Instructions ...

Page 2: ......

Page 3: ...ge LED display from a distance and the panel can also forward signals to a Caregiver Alert Pager that will display call type and device ID Alarms can be reset using a wireless reset button cordless monitor pager or at the panel Straightforward programming allows users to quickly set up the system and easily add remove devices based on changes in daily requirements ...

Page 4: ... pre configured to operate with your kit If not refer to programming section below for details 1 4 Adjust volume to desired level by using the wheel on the right side of the monitor Tracking should only be ON if mobile devices wheelchairs or pendant call buttons are in use Otherwise set this switch to OFF Switch on the button lock to prevent accidental activation of the buttons on the front of the...

Page 5: ...can be useful if several panels are in use and will ensure pagers only receive alarms from their area Tap SELECT1 until the tens digit displays A Use SELECT2 to set 0 7 This setting must match whatever has been selected on the wireless devices in the area Pause Setting This allows a caregiver to pause the panel for a programmable interval allowing patients to be removed from their beds without tri...

Page 6: ...t A Alarm delays 10min after bed exit B Alarm delays 15min after bed exit C Alarm delays 20min after bed exit D Alarm delays 25min after bed exit E Alarm delays 30min after bed exit F Alarm delays 35min after bed exit Pager Code Setting a pager code can be useful if several panels are in use and will ensure pagers only receive alarms from their area Tap SELECT1 until the tens digit displays C Use ...

Page 7: ...t and RESET to adjust the units if the monitor will be moved to a new room For t 3 the display settings cannot be adjusted and the monitor will display AP to indicate it is ready for auto pairing Take the monitor next to the RG43 panel to synchronise the displays On RG43 Hold PROGRAM REVIEW for 5s to enter pairing mode The RG43 will briefly display AP and all devices paired with the RG2 monitor wi...

Page 8: ...and a beep will sound if AC is lost Panel Battery This indicates the status of the panel only It will flash if there is low battery or batteries have not been inserted This LED can only be reset by changing the batteries The two LEDs next to the large digits indicate the status of wireless devices Signal Lost will turn on if tracking is active and the panel cannot detect one of the devices in memo...

Page 9: ...to a memory slot to give a totally wireless falls man agement solution If multiple devices are programmed into a single memory slot this will reset any alarm from the slot into which it has been paired When using wireless reset buttons Ramblegard recommends holding the button for 3s to ensure the panel receives the signal Cordless Monitors Cordless RG2 monitors can now be used as a kit together wi...

Page 10: ...r local distributor with details for further assistance Signal Lost If a device is displaying as signal lost on the RG43 panel you can silence this indication by pressing RESET The SIGNAL LOST LED will continue to flash until the device has been brought back into range or is removed from memory If you would like to remove this device from the panel memory hold REVIEW RESET for 3s The RG43 panel wi...

Page 11: ......

Page 12: ...T 028 9448 3971 www ramblegard com S E CareTrade t a Ramblegard Elmfield House Rathenraw Industrial Estate Greystone Road Antrim BT41 2SJ ...

Reviews: