1-800-563-4382
RAM Ele Lifts
24
5)
Run the lift upwards with a moderate load (approx. 200lbs) until it stops automatically
and measure the vertical distance “D” from the platform to the upper landing (the
platform should stop below the upper landing). Translate this measurement to the tube
that the upper limit bracket slides on.
6)
7)
Adjust the upper limit bracket by moving it up distance “D”.
8)
Run the platform down and back up again to confirm the lift stops level with the upper
landing automatically.
Note
After the next step, fine adjustment is more difficult, so make sure that you are happy with the
position of the bracket at this point.
9)
Use the
new
self tapping locking screw that is taped the bracket to pin the upper limit
bracket securely in place.
Distance
“D”
Distance
“D”
5