Raisecom
RC1104-FE-4W (A) User Manual
6 Network management features
Raisecom Technology Co., Ltd.
19
No.
Item
Value
Description
52
G. Interface Current 24-Hour Statistics
Table
Uncontrollable and
read-only
53
G. Interface Current Recent 7×24-Hour
Statistics
Table and K-line diagram
Uncontrollable and
read-only
54
G. Interface: LOS Times
N
Uncontrollable and
read-only
55
G. Interface: LOSW Times
N
Uncontrollable and
read-only
56
G. Interface: LOLNK Times
N
Uncontrollable and
read-only
57
G. Interface: CV Times
N
Uncontrollable and
read-only
58
G. Interface: ES(s)
N
Uncontrollable and
read-only
59
G. Interface: SES(s)
N
Uncontrollable and
read-only
60
G. Interface: UAS(s)
N
Uncontrollable and
read-only
61
G. Interface: LOSW(s)
N
Uncontrollable and
read-only
6.2 Configuring device
All configurable items in the table above can be configured, such as Tx rate, Rx rate, and
electrical interface. However, the slave device can be configured through remote management
only. The slave device cannot be configured locally even though you can query its status after
the device is inserted into the 16-slot chassis.
There are some requirements on the G. interface rate, Annex type, and codding mode. If these
requirements are not met, the device may work improperly. The device determines the rate
range according to the Annex type and coding mode.
Table 6-2
Determining the rate range according to the Annex type and coding mode
–
Annex type
Coding mode
Max./Min. rate (64 Kbit/s)
Possible
combinations
Annexa/Annexb
pam4
1–2
pam16
3–36
Annexa_f/
Annexb_g
pam16
3–60
pam32
12–89
pam64
12–178