MANUAL OPERATION
(Only possible, when MANUAL knob is used)
Access to the pilot burner is only required for ignition with a
match.
When turning main valve knob, do not force. Knob has a slip
clutch that clicks until the end stops are reached. This allows for
manual flame height adjustment as well as adjustment to pilot
standby position.
1.
STOP!
Read the safety information included before proceeding.
2. Turn main valve knob to the
OFF
, full clockwise
position.
3. Turn MANUAL knob to the
MAN
, full clockwise
position.
4. Place ON / OFF switch (if equipped) in
O
(OFF) position.
5. Wait five (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the floor.
If you detect gas STOP! Follow “WHAT TO DO IF YOU
SMELL GAS” in the safety information on page 2.
If no gas
is present, proceed to step 6.
6. Place ON / OFF switch (if equipped) in
I
(ON)
position.
7. With the MANUAL knob in
MAN
position a manual pilot valve
operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in, to
start pilot gas flow (see figure 32).
Ignition with match:
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) minute
after the pilot is lit. Release manual pilot valve operator. If pilot
does not stay lit, wait five (5) minutes and repeat.
Ignition with piezo ignitor:
Change the ignition cable from the receiver to the valve. Push
in the piezo ignitor to ignite. If pilot does not stay lit, wait five (5)
minutes and repeat.
If the pilot does not stay lit after several tries, turn the gas
control knob (main valve knob) to
OFF
and proceed to step 12.
9. If applicable, replace pilot access panel before proceeding.
10. Turn MANUAL knob to the
ON
, full counterclockwise
position.
11. Turn main valve knob to the full
ON
, full counterclockwise
position.
12. If the appliance will not operate, follow the instructions TO
TURN OFF GAS TO APPLIANCE (below).
Figure 32: Combination control, cover
8 Wire
Receiver Jack
Microswitch
MANUAL Knob
in MAN Position
Main Valve Knob
in OFF Position
Manual Pilot
Valve Operator
Piezo Ignitor
(optional)
ON / OFF Switch
(optional) in
ON Position
Connection
Piezo Ignitor Tab
2.8 x 0.8 mm
TO TURN OFF GAS TO APPLIANCE
1. Place ON / OFF switch (if equipped) in
O
(OFF) position.
2. If gas control is accessible turn main valve knob to the
OFF
full
clockwise
position.
AUTOMATIC TURN DOWN TO PILOT
3 Hour No Communication Function
▪ The valve will turn to pilot flame if there is no communication
between handset and receiver for a 3 hour period. The fire will
continue to function normally when communication is restored.
Receiver Overheating
▪ Powered by mains adapter: The valve turns to pilot flame if the
receiver temperature is higher than 176 °F (80 °C). If batteries
are installed in the receiver in this configuration the temperature
must not exceed 60 °C.
▪ Powered by batteries and/or connected to the V module: The
valve turns to pilot position if the temperature in the receiver is
higher than 140 °F (60 °C).
NOTE:
When the receiver temperature is below 140 °F (60 °C),
the main burner can be turned ON manually. In Thermo-
static Mode, the main burner turns ON automatically.
1 Hour Turn Down
(optional; requires special receiver and handset software)
▪ The valve will turn to pilot flame if there is no motor movement
over a 1 hour period.
AUTOMATIC SHUT OFF
Countdown Timer
▪
At end of countdown time period, the fire shuts off. The Count-
down Timer only works in Manual, Thermostatic, and Eco
Modes. Maximum countdown time is 9 hours and 50 minutes.
Low Battery Receiver
▪ With low battery power in the receiver the system shuts off the
fire completely. This will not happen if the power supply is inter-
rupted.
On-Demand Pilot
▪ This green feature eliminates gas energy consumption during
extended appliance inactivity. When the appliance is inactive
for an extended period of time the system automatically extin-
guishes the pilot. This feature helps the consumer realize cost
benefits by automatically eliminating energy consumption dur-
ing non-heating months and limited use.
▪ The programmed length of inactivity to activate the system is
specified by the appliance manufacturer and cannot be altered
in the field.
2
nd
Thermocouple Shut Off
(optional)
▪ The system shuts off the fire if the main burner does not com-
pletely ignite approximately 20 seconds after ignition or after
pushing button.
NOTE:
Before the next ignition there is a 2 minute waiting pe-
riod. If the thermocouple is then still too hot, you will
hear a long beep.
Summary of Contents for VIVA L Series
Page 7: ...13 Vertical Roof Termination on angle 14 Vertical Roof Termination with bends...
Page 14: ...24 25...
Page 15: ...26 27...
Page 19: ...31 Viva 100 LG with side glass 32 Viva 120 L without side glass...
Page 20: ...33 Viva 120 LG with side glass 34 Viva 160 L without side glass...
Page 21: ...35 Viva 160 LG with side glass 36 Appendix 2 Mertik Symax controls...